Results 101 to 110 of about 19,278,359 (237)

Recombinant human immunoglobulin (Ig)A1 and IgA2 anti‐D used for detection of IgA deficiency and anti‐IgA

open access: yes, 2008
To avoid anaphylactic reactions, immunoglobulin (Ig)A-deficient patients with anti-IgA should be transfused with IgA-deficient blood components. There is a need for fast and robust assays for demonstration of IgA deficiency and for detection of anti ...
Morten H. Dziegiel   +3 more
core   +1 more source

Investigation of Complement Activation and Cytokine Signatures in AQP4+ NMOSD, MOGAD, and MS

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective Aquaporin‐4‐IgG seropositive neuromyelitis optica spectrum disorder (AQP4+ NMOSD), myelin oligodendrocyte glycoprotein antibody‐associated disease (MOGAD), and multiple sclerosis (MS) are pathophysiologically distinct neuroinflammatory disorders. Complement activation is a major mechanism of injury in AQP4+ NMOSD, whereas its role in
Angeliki G. Filippatou   +23 more
wiley   +1 more source

F(ab’)2-Fragments of Antirabic Immunoglobulin Production Using Immobilized Pepsin

open access: yes, 2008
Biotechnological scheme for F(ab')2-fragments of anti-rabies immunoglobulin production using immobilized pepsin was developed. Optimal ways for immobilized pepsin production were determined, conditions for fermentative hydrolysis of anti-rabies ...
L. V. Savitskaya   +10 more
core   +1 more source

Clinical Characteristics and Concordance of Anti‐MDA5 Antibodies: A Multicenter Australian Study

open access: yesArthritis Care &Research, EarlyView.
Objective In Australia, anti‐MDA5 antibodies are exclusively tested by a line immunoblot assay (LIA). The clinical concordance of an LIA‐positive anti‐MDA5 result is unclear. We aimed to describe the clinical features and determine the clinical concordance of patients with anti‐MDA5 antibodies. Methods Electronic records of a multisite cohort (patients
Syed B. Ali   +11 more
wiley   +1 more source

Prophylactic anti-D preparations display variable decreases in Fc-fucosylation of anti-D.

open access: yes, 2015
Background RhIG is obtained from hyperimmunized healthy anti-D donors (HIDs) boosted with D+ red blood cells (RBCs). One hypothesis for its mechanism of action is fast clearance of opsonized D+ RBCs through Fcγ receptor (FcγR)III.
Agnes Hipgrave Ederveen   +24 more
core   +1 more source

Antibody‐Protein L Functionalized Microparticles for Detection of Surface Markers in Heterogeneous Colorectal Lesions

open access: yesAdvanced Healthcare Materials, EarlyView.
Personalized targeting of colorectal cancer (CRC) is challenged by the heterogeneity of the disease and its variable display of tumor surface markers. Antibody‐Protein L Microparticles (APL‐MPs) leverage the antibody‐binding property of Protein L in a swappable system, enabling easy application to variable targets for personalized therapies.
Saleh Ramezani   +11 more
wiley   +1 more source

Midwives' experience of offering anti-D immunoglobulin to women: The importance of choice

open access: yes, 2016
BackgroundInformed decision making around anti-D immunoglobulin (Ig) is important but complex, requiring consideration of individual factors to reach the most appropriate choices for individual women.
Mairi Harkness   +5 more
core   +1 more source

A 3D‐Printed Model of Human Lactation

open access: yesAdvanced Healthcare Materials, EarlyView.
Breastfeeding supports infant and maternal health, yet in vitro models that mimic human lactation remain scarce. Here, light‐based 3D printing creates high‐resolution, alveoli‐inspired microwells that guide breast cells into polarized microtissues. The printed scaffolds embed slow‐release prolactin microcrystals to deliver hormonal cues, enabling human
Amelia Hasenauer, Marcy Zenobi‐Wong
wiley   +1 more source

A Wearable Microfluidic Sweat‐Patch Pilot Study for Detecting Breast‐Cancer Proteins CEA and PIP/GCDFP‐15

open access: yesAdvanced Healthcare Materials, EarlyView.
A passive capillary‐driven microfluidic patch standardizes noninvasive sweat collection from the axilla and chest during exercise. Paired sweat and capillary blood samples enable laboratory ELISA analysis of CEA and PIP. CEA is detectable but often below quantification limits, while PIP remains undetectable in sweat.
Fatemeh Esmaeildoost   +7 more
wiley   +1 more source

Home - About - Disclaimer - Privacy