Results 241 to 250 of about 1,002,093 (329)

Radial multi‐echo bSSFP and IDEAL chemical shift separation in k‐space for high‐speed 3D hyperpolarized 13C metabolic MRI

open access: yesMagnetic Resonance in Medicine, EarlyView.
Purpose Hyperpolarized (HP) carbon‐13 (13C) MRSI provides real‐time information about metabolic processes but lacks high temporal and spatial resolution. This study introduces a multi‐echo–balanced steady‐state free precession (ME‐bSSFP) method with a 3D radial readout trajectory in a spiral phyllotaxis pattern as a method for non‐Cartesian HP 13C MRSI
Zirun Wang   +12 more
wiley   +1 more source

Donor procurement for intestinal transplantation [PDF]

open access: yes, 1997
Abu-Elmagd, K   +5 more
core  

Measurement of renal cortex perfusion: A direct comparison of arterial spin labelling magnetic resonance imaging and [15O]H2O positron emission tomography

open access: yesMagnetic Resonance in Medicine, EarlyView.
Abstract Purpose Reliable information about renal blood supply is important to understand kidney physiology and diseases. Arterial spin labeling MR (ASL‐MR) imaging and [15O]H2O positron emission tomography (PET) can noninvasively measure tissue perfusion but have never been directly compared.
Naja Enevold Olsen   +9 more
wiley   +1 more source

Time‐resolved mapping of myocardial stiffness using 2D multifrequency spiral MR elastography with and without external vibration

open access: yesMagnetic Resonance in Medicine, EarlyView.
Abstract Purpose There is a clinical need for stiffness mapping of the heart; however, current cardiac magnetic resonance elastography (cMRE) has limited spatiotemporal resolution. Therefore, we developed 2D spiral multifrequency MRE of the human heart and conducted a study to analyze the consistency and reproducibility of motion‐encoding and stiffness
Matthias S. Anders   +14 more
wiley   +1 more source

A Case of Hemorrhagic Shock for a Ruptured Splenic Aneurysm Treated With REBOA-Assisted Surgery. [PDF]

open access: yesCase Rep Surg
D'Alterio C   +5 more
europepmc   +1 more source

Flow‐suppressed 2D spin‐echo imaging with high tolerance to B1 inhomogeneity using hyperbolic secant pulses

open access: yesMagnetic Resonance in Medicine, EarlyView.
Abstract Purpose To demonstrate flow‐suppressed two‐dimensional (2D) spin‐echo and spin‐echo diffusion echo‐planar imaging (EPI) sequences using hyperbolic secant (HS) pulses for both π/2 excitation and π refocusing. Theory and Methods A theoretical framework to derive phase dispersion of moving spins under π/2 excitation and π refocusing using HS ...
Jae‐Youn Keum   +3 more
wiley   +1 more source

Asymptomatic Migration of an Amplatzer Vascular Plug into the Distal Abdominal Aorta. [PDF]

open access: yesVasc Specialist Int
Maleux G   +4 more
europepmc   +1 more source

Home - About - Disclaimer - Privacy