Results 71 to 80 of about 945,421 (255)
Cor‐Knot automated fastener in distal anastomosis of total aortic arch replacement: A case report
Cor‐Knot fastener use in sternotomy‐based aortic arch procedures has not been reported. We present Cor‐Knot fastener use over a Hegar dilator in an anatomically challenging total aortic arch replacement with no short‐term and/or long‐term complications.
Omar M. Sharaf +2 more
doaj +1 more source
ABSTRACT Limited access to cadavers necessitates the availability of digital resources for anatomy education. Smartphone‐based photogrammetry offers a promising solution for creating three‐dimensional (3D) and augmented reality (AR) models. This study compared two mobile photogrammetry applications (Qlone and Polycam) that have been used in modern ...
Sarita Phukwantong +3 more
wiley +1 more source
Asymptomatic double aortic arch [PDF]
Muzaffer Sariaydin1, Serhat Findik1, Atilla Guven Atici1, Sevket Ozkaya2, Aziz Uluisik11Department of Pulmonary Medicine, Faculty of Medicine, Ondokuz Mayis University, Samsun, Turkey; 2Department of Pulmonary Medicine, Faculty of Medicine, Rize ...
Uluışık, Aziz +8 more
core +1 more source
Background This study compared limited aortic repair (ascending, and /or hemi-arch replacement) versus extended-arch repair (ascending, arch and proximal descending aortic replacement) used for patients aged 65 or older, who had type A acute aortic ...
Wei Qin +5 more
doaj +1 more source
Successful Percutaneous Retrieval of an Embolized MitraClip From the Right Subclavian Artery
ABSTRACT Single leaflet device attachment (SLDA) after mitral transcatheter valve edge‐to‐edge repair (M‐TEER) has been reported in up to 5% of patients. However, complete embolization of the M‐TEER device is exceedingly rare. Device retrievals in all previously reported cases were completed by vascular surgery cut down at the end. In this case, we are
Seyed Hossein Aalaei‐Andabili +2 more
wiley +1 more source
ABSTRACT Objectives To evaluate the feasibility and short‐term outcomes of transcatheter aortic valve replacement (TAVR) using balloon‐expandable Sapien valves in patients with prior endovascular aortic stent grafts. Methods We conducted a single‐center, retrospective study of 23 patients with prior endovascular aortic stent grafts who underwent TAVR ...
Iad Alhallak +8 more
wiley +1 more source
The successes of thoracic endovascular aortic repair (TEVAR) have spurned new approaches to addressing thoracic aortic pathologies. These hybrid techniques offer an alternative in patients with multi-segmental thoracic aortic pathologies which would have
Czerny, Martin +3 more
core +1 more source
Should the transverse aortic arch be replaced simultaneously with aortic root replacement for annuloaortic ectasia in marfan syndrome? [PDF]
ObjectiveThe purpose of this study was to determine, on the basis of the late fate of the intact aortic arch with abnormal tissue after aortic root replacement, whether the intact aortic arch should be replaced prophylactically at the time of aortic root
Tagusari, Osamu +10 more
core +1 more source
Objective: The aim of this retrospective single-center study was to report a novel hybrid technique of replacement of the ascending aorta and implantation of fenestrated stent-graft of the entire aortic arch for Stanford type A aortic dissection and to ...
Xiantao Ma, MD, PhD +5 more
doaj +1 more source
Midterm Results of Aortic Arch Replacement in a Stanford Type A Aortic Dissection With an Intimal Tear in the Aortic Arch [PDF]
Stanford type A aortic dissection is a potentially catastrophic event that requires surgical repair, on an emergency basis. The extent of arch repair that should be carried out during emergency surgery of this type is controversial. This study was designed to evaluate the results of arch replacement carried out during acute type A dissection.28 ...
Cho, Seong Ho +7 more
openaire +2 more sources

