Results 161 to 170 of about 17,527,148 (207)
Current pharmacy practice guidelines recommend 24-h area-under-curve (AUC24) targets for use of vancomycin against methicillin-resistant Staphylococcus aureus (MRSA). AUC protocol-specific vancomycin orders were begun recently (2022) at our institution.
Douglas F Stickle
exaly +4 more sources
Quantification of Thermal Dose in Moderate Clinical Hyperthermia With Radiotherapy: A Relook Using Temperature–Time Area Under the Curve (AUC) [PDF]
BACKGROUND Thermal dose in clinical hyperthermia reported as cumulative equivalent minutes (CEM) at 43 °C (CEM43) and its variants are based on direct thermal cytotoxicity assuming Arrhenius 'break' at 43 °C. An alternative method centered on the actual time-temperature plot during each hyperthermia session and its prognostic feasibility is explored ...
Oliver Riesterer +2 more
exaly +4 more sources
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Doing More With Less: Pragmatic Implementation of Vancomycin Area-Under-the-Curve (AUC) Monitoring
Journal of Pharmacy Practice, 2021Universal area-under-the-curve (AUC) guided vancomycin therapeutic drug monitoring (TDM) is resource-intensive, cost-prohibitive, and presents a paradigm shift that leaves institutions with the quandary of defining the preferred and most practical method for TDM.
Joanne Huang +4 more
openaire +2 more sources
Biopharmaceutics and Drug Disposition, 1995
AbstractSix numerical integration algorithms based on linear and log trapezoidal methods as well as four cubic‐spline methods were proposed for estimation of area under the curve (AUC). These six different algorithms were implemented using IMSL/IDLTM command language and evaluated using data simulated under five different dosing conditions and two ...
Francis L S Tse
exaly +3 more sources
AbstractSix numerical integration algorithms based on linear and log trapezoidal methods as well as four cubic‐spline methods were proposed for estimation of area under the curve (AUC). These six different algorithms were implemented using IMSL/IDLTM command language and evaluated using data simulated under five different dosing conditions and two ...
Francis L S Tse
exaly +3 more sources
CYCLOSPORIN A (CyA) MONITOrING BY CALCULATION OF AREA UNDER THE CURVE (AUC)
Nephrology, 2000Background The introduction of CyA resulted in a significant prolongation in renal transplant survival but was complicated by the difficulty in distinguishing between transplant rejection and drug toxicity. More recently the conversion of stable transplant recipients to the microemulsion form of CyA resulted in significant nephrotoxicity at trough ...
Goodman D +3 more
openaire +1 more source
An alternative approach to calculating Area‐Under‐the‐Curve (AUC) in delay discounting research
Journal of the Experimental Analysis of Behavior, 2016Applied to delay discounting data, Area‐Under‐the‐Curve ( AUC ) provides an atheoretical index of the rate of delay discounting. The conventional method of calculating AUC , by summing the areas of the trapezoids formed by successive delay‐indifference ...
Allison M, Borges +3 more
openaire +2 more sources
Biopharmaceutics and Drug Disposition, 1997
A limited sampling model has been developed for flunarizine following a 30 mg oral dose in epileptic patients who were receiving phenytoin or carbamazepine or both, to estimate the area under the curve (AUC) and maximum plasma concentration (Cmax).
Iftekhar Mahmood
exaly +3 more sources
A limited sampling model has been developed for flunarizine following a 30 mg oral dose in epileptic patients who were receiving phenytoin or carbamazepine or both, to estimate the area under the curve (AUC) and maximum plasma concentration (Cmax).
Iftekhar Mahmood
exaly +3 more sources
Journal of Pharmacokinetics and Biopharmaceutics, 1992
The usual formulas for the extrapolated values of AUC and AUMC from tn to infinity produce estimates that are biased. An empirical correction factor is shown to reduce both bias and variance of estimates. The fitted value Cz at the last time-point tn should normally be used in the formulas, rather than the measured concentration Cn.
openaire +2 more sources
The usual formulas for the extrapolated values of AUC and AUMC from tn to infinity produce estimates that are biased. An empirical correction factor is shown to reduce both bias and variance of estimates. The fitted value Cz at the last time-point tn should normally be used in the formulas, rather than the measured concentration Cn.
openaire +2 more sources
2019 2nd International Conference on Advancements in Computational Sciences (ICACS), 2019
Software defect prediction (SDP) models are used to improve effort and testing estimate of software by identifying defective modules beforehand. Precision, recall/true positive rate and false positive rate have been used to evaluate the performance of models.
Zeeshan Ali Rana
exaly +3 more sources
Software defect prediction (SDP) models are used to improve effort and testing estimate of software by identifying defective modules beforehand. Precision, recall/true positive rate and false positive rate have been used to evaluate the performance of models.
Zeeshan Ali Rana
exaly +3 more sources
Journal of Pharmacokinetics and Biopharmaceutics, 1992
Eleven numerical methods for estimation of AUC (including 4 new methods) and 22 methods for AUMC (including 8 new methods) were tested on large simulated noisy datasets representing bolus, oral and infusion concentration-time profiles. Some methods were unacceptable because their mean error was large; these included a commonly recommended form of the ...
openaire +2 more sources
Eleven numerical methods for estimation of AUC (including 4 new methods) and 22 methods for AUMC (including 8 new methods) were tested on large simulated noisy datasets representing bolus, oral and infusion concentration-time profiles. Some methods were unacceptable because their mean error was large; these included a commonly recommended form of the ...
openaire +2 more sources

