Results 161 to 170 of about 316,523 (303)

Lyophilized Synthetic Platelets: In Vitro Characterization and in Vivo Evaluation in Mouse Thrombocytopenia Model

open access: yesAdvanced Science, EarlyView.
ABSTRACT Platelet transfusions to treat bleeding complications use donor‐derived platelets stored at room‐temperature, that have a shelf‐life of only 5–7 days due to bacterial contamination risks. Cold‐stored and freeze‐dried platelets are being investigated for extending shelf‐life, but these still have the inherent challenge of donor‐dependency.
Ujjal Didar Singh Sekhon   +20 more
wiley   +1 more source

Arm Injury - Carpentry

open access: yesMedicine & Science in Sports & Exercise, 2019
Dylan Homen   +4 more
openaire   +2 more sources

Friend, Not Foe: Lowered Tissue Reactivity to Long‐Term Polyimide Implants

open access: yesAdvanced Science, EarlyView.
The choice of optimal neural probe designs remains a major challenge in the field of neurotechnology. This study investigated the biocompatibility of several probe variations, including material, thickness, width, and implantation strategy. It highlights the clear advantage of soft polyimide probes over stiff silicon probes for better device ...
Corinne Orlemann   +11 more
wiley   +1 more source

Artificial Piezoelectric Interface Enables Ultrafast Interfacial Ion Kinetic for Highly‐Sensitive Piezoionic Sensors

open access: yesAdvanced Science, EarlyView.
This study proposes a piezoelectric interface modification strategy to amplify the piezoionic effect. The piezoelectric interface generates an intrinsic electric field, which not only drives rapid ion migration but also concentrates polarized ions on the interface. The flexible sensor delivers superior performance, such as a quick response rate, strong
Yanyu Chen   +5 more
wiley   +1 more source

Concurrently Achieving 4.6 W/M2 and 120,000 Cyclability Enabled by Extendable Swing Arms in Rotational Triboelectric Nanogenerator

open access: yesAdvanced Science, EarlyView.
A rotational energy harvesting device that successfully reconciles high power density with mechanical durability through a hybrid sliding‐and‐bouncing kinematic mechanism is reported. The success reported in our paper includes addressing a dilemma where enhanced electrical output comes at the cost of increased friction and wear, limiting the practical ...
Yihong Lin   +12 more
wiley   +1 more source

Comparison of functional and patient-reported outcomes following acute, chronic, and nonoperative distal biceps tendon rupture treatments. [PDF]

open access: yesJSES Rev Rep Tech
Saini J   +9 more
europepmc   +1 more source

Dynamic Self‐Clickable Decellularized Matrix Hydrogels for Regulating Vascularity and Enhancing Muscle Regeneration

open access: yesAdvanced Science, EarlyView.
Dynamic decellularized hydrogels are prepared using bovine decellularized small intestine submucosa (SIS) norbornene (dSIS‐NB). Bovine dSIS contained significant amounts of disulfide‐rich fibrillin‐I, enabling ‘self‐clickable’ thiol‐norbornene gelation and spatiotemporal tuning of hydrogel physicochemical properties.
Van Thuy Duong   +4 more
wiley   +1 more source

Injectable Hydrogel with Rapid Coagulation, Low Swelling, and High Burst Pressure Tolerance Properties for Long‐Term Management of Bleeding Wound

open access: yesAdvanced Science, EarlyView.
An injectable PACmC hydrogel with “rigid island‐flexible chain” architecture is developed, featuring low swelling (49.2% within 7 d), strong wet adhesion (46.5 kPa), and high burst pressure (701 mm Hg), which can achieve rapid hemostasis and long‐term sealing in rabbit and porcine models of hepatic and splenic hemorrhage.
Yang Ouyang   +12 more
wiley   +1 more source

Arm Injury - Crossfit

open access: yesMedicine & Science in Sports & Exercise, 2019
Jeremy Hreha   +4 more
openaire   +2 more sources

Home - About - Disclaimer - Privacy