Results 21 to 30 of about 7,913 (283)
A new numerical model for simulating the propagation and quenching of a detonation wave in in-line flame arrester was developed by using FORTRAN language.
ShaoChen Sun +5 more
doaj +1 more source
Overvoltage is a critical problem of Thailand’ distribution system. The electrical protection device in the distribution system needs to be able to support this level of overvoltage.
Chaiyaporn Lothongkam +2 more
doaj +1 more source
Analisa Pengaruh Letak Lightning Arrester untuk Memproteksi Trafo Daya Terhadap Tegangan Lebih
Seiring dengan meningkatnya konsumen energi listrik di Indonesia, penyaluran energi listrik kepada konsumen di harapkan dapat berjalan dengan lancar.
Andika Putra +2 more
doaj +1 more source
[No abstract available]
Atheir, Abbas, Bryan L, Roth
openaire +2 more sources
Development of a ±660 kV DC transmission line arrester
In order to improve the lightning withstand level of ±660 kV DC transmission line in China, the authors had begun to develop the ±660 kV DC line arrester since 2014, which was developed successfully in 2016.
Shanqiang Gu +6 more
doaj +1 more source
DC Side Over-Voltage Characteristics Analysis of AC/DC Hybrid Distribution Power System
AC/DC hybrid power distribution network are adopted to replace traditional AC power distribution network with the continuous access of distributed renewable energy to power grid, which can solve the source and load power supply as well as power ...
Zhanqing Yu +4 more
doaj +1 more source
The effects of flame speed and explosion pressure on the flame-quenching performance of an in-line crimped-ribbon flame arrester was investigated using propane, ethylene, and hydrogen/air mixtures.
Shaochen Sun +4 more
doaj +1 more source
In zinc oxide (ZnO) surge arresters, leakage current usually flows across the arrester under normal operating condition. Leakage current is one of the factors which contribute towards degradation of surge arresters and therefore, it is very important to ...
Nurul A. A. Latiff +3 more
doaj +1 more source
Field test‐based research on current sharing characteristics of multicolumn parallel arresters
A converter station is the hub of a High Voltage Direct Current (HVDC) transmission project, and the neutral bus arrester on its rectifier side has the most complex operation condition.
Youping Fan +6 more
doaj +1 more source
Studi Pengaruh Kelembapan dan Polutan pada Kinerja Isolator Arrester 20 kV
Arrester merupakan sebuah perangkat yang berfungsi untuk melindungi peralatan dari kegagalan dielektrik yang disebabkan oleh impuls petir, switching surge, ataupun lonjakan tegangan yang melebihi kemampuan dielektrik suatu peralatan.
Naufal Hilmi Fauzan +3 more
doaj +1 more source