Results 171 to 180 of about 174,809 (302)

Diabetic Peripheral Neuropathy: Molecular Staging, Risk Factors, Therapeutics, and Emerging Trends

open access: yesMed Research, EarlyView.
The heterogeneous landscape of DPN can be unified through a tripartite pathogenic model encompassing progressive stages of metabolic dysregulation, chronic inflammation, and overt neuronal damage. Within this framework, six clinical subtypes were identified, namely, hyperglycemia‐driven, dyslipidemia‐driven, inflammation‐driven, dysvascularity‐driven ...
Xiaofeng Dai, Mingze Tang
wiley   +1 more source

Biodegradable Natural Polymer‐Based Drug Delivery Systems for Bone Tissue Engineering

open access: yesMedicinal Research Reviews, EarlyView.
ABSTRACT The increasing incidence of bone diseases and injuries, especially among aging populations, has underscored the shortcomings of traditional treatments such as bone grafts and metal implants, which often face complications including immune rejection, mechanical failure, and delayed healing.
Hyejin Jo   +4 more
wiley   +1 more source

K‐CC‐MoCo: A Fast k‐Space‐Based Respiratory Motion Correction for Highly Accelerated First‐Pass Perfusion Cardiovascular MR

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose First‐pass perfusion cardiovascular MR (FPP‐CMR) enables the non‐invasive diagnosis of microcirculation and coronary artery disease. In free‐breathing FPP‐CMR, motion correction is usually performed in the image domain, requiring an initial reconstruction.
Elisa Moya‐Sáez   +10 more
wiley   +1 more source

FMRI Approaches to Mapping Cerebrovascular Reactivity: Comparison of Gradient Echo BOLD and Spin Echo BOLD With Arterial Spin Labeling

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To compare markers of cerebrovascular reactivity (CVR) measured with Gradient Echo (GE, T2*w) and Spin‐Echo (SE, T2w) BOLD fMRI with quantitative physiological CVR measured using ASL. Methods CVR, the ability of blood vessels to dilate and increase cerebral blood flow (CBF), can be investigated with ASL fMRI but has a low signal‐to ...
Sara Pomante   +13 more
wiley   +1 more source

Simultaneous Cerebral Blood Flow and Cerebrovascular Reactivity Obtained From Novel Multi‐Band Multi‐Echo Pseudo‐Continuous Arterial Spin Labeling (M2‐PCASL) Sequence: A Test–Retest Reliability Study

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose We aim to assess the reliability of cerebral blood flow (CBF) and cerebrovascular reactivity (CVR) obtained simultaneously from a novel multi‐band pseudo‐continuous arterial spin labeling (M2‐PCASL) sequence and hypercapnic gas challenge, to examine factors influencing CBF variability, and to evaluate the impact of carbon dioxide (CO2)
Jody Todd   +3 more
wiley   +1 more source

Bright Ferritin for Non‐Invasive MRI Monitoring of the Fate of Transplanted hPSC‐Cardiomyocytes in the Infarcted Rat Heart

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To demonstrate that a recently reported bright ferritin magnetic resonance imaging (MRI) platform can track transplanted human pluripotent stem cell (hPSC)‐derived cardiomyocytes (hPSC‐CMs) longitudinally and on‐demand in the rat heart.
Keyu Zhuang   +12 more
wiley   +1 more source

Respiration Can Trigger Cerebrovascular Reactivity: A Novel Method to Quantify Cerebrovascular Resistance Dynamics Using Real‐Time Phase‐Contrast MRI

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To directly quantify respiration‐driven cerebrovascular resistance dynamics (CRD) using a gas‐free MRI framework based on the internal‐to‐external artery carotid flow ratio (ratio_Q). Theory and Methods Two independent datasets (n = 10 and n = 17) were used to evaluate repeatability and to compare breathing conditions.
Pan Liu   +5 more
wiley   +1 more source

Home - About - Disclaimer - Privacy