Results 81 to 90 of about 491,319 (340)

Arterial stenosis, pressure, and flow

open access: yesThe Journal of Thoracic and Cardiovascular Surgery, 1976
The interaction between the effects of an arterial stenosis and postocclusion hyperemia was studied in a model of the capillaron system. A capillaron is a module consisting of soft-walled permeable vessels (capillaries) in a compliant capsule. Stenosis reduced flow in accord with arterial cross-sectional area. Addition of a capillaron reduced flow to a
Simon Rodbard, Yutaka Kikuchi
openaire   +3 more sources

Gasotransmitters in Modern Medicine: Promises and Challenges in the Use of Porous Crystalline Carriers

open access: yesAdvanced Healthcare Materials, EarlyView.
This perspective provides an overview of the growing interest in utilizing various gasotransmitters—small gaseous signaling molecules namely nitric oxide (NO), carbon monoxide (CO), and hydrogen sulfide (H2S)—for several therapeutic applications, with emphasis on the potential use of porous materials as carriers to provide safe and controlled local ...
Rosana V. Pinto   +2 more
wiley   +1 more source

Non‐Surgical, In‐Stent Membrane Bioelectronics for Long‐Term Intracranial Pressure Monitoring

open access: yesAdvanced Healthcare Materials, EarlyView.
This image shows a sequence of long‐term intracranial pressure monitoring using non‐surgical, in‐stent membrane bioelectronics. Abstract Traditional intracranial pressure (ICP) monitoring methods, using intraventricular catheters, face significant limitations, including high invasiveness, discrete data, calibration complexities, and drift issues, which
Jimin Lee   +9 more
wiley   +1 more source

Cardiovascular Parameters in a Swine Model of Normobaric Hypoxia Treated With 5-Hydroxymethyl-2-Furfural (5-HMF)

open access: yesFrontiers in Physiology, 2019
Introduction:The consequences of low partial pressure of O2 include low arterial O2 saturations (SaO2), low blood O2 content (CaO2), elevated mean pulmonary artery pressure (PAP), and decreased O2 consumption VO2. 5-hydroxymethyl-2-furfural (5-HMF) binds
Richard Thomas Mahon   +3 more
doaj   +1 more source

Effect of hypertension on low-density lipoprotein transport within a multi-layered arterial wall: modelling consistent with experiments [PDF]

open access: yesarXiv, 2016
The influence of hypertension on low-density lipoproteins intake into the arterial wall is an important factor for understanding mechanisms of atherosclerosis. It has been experimentally observed that the increased pressure leads to the higher level of the LDL inside the wall.
arxiv  

Biohybrid Vascular Graft Made of Textile‐Reinforced Elastin‐Like Recombinamers and Its Preservation via Drying Processes

open access: yesAdvanced Healthcare Materials, EarlyView.
Clinical translation of biohybrid medical implants requires the previous implementation of drying schemes that can facilitate their sterilization and storage. This study addresses that critical aspect and elucidates the impact of drying on biohybrid vascular grafts, highlighting the need for implant‐specific drying strategies to ensure safety ...
Dominic Pascal Andre   +5 more
wiley   +1 more source

Arterial pressures in a general practice

open access: yesAnnals of Human Biology, 1974
Systolic and diastolic readings of blood pressure were recorded for 5386 (2585 males and 2801 females) members of a general practice situated in and around Ballycastle, County Antrim. Polynomials to predict blood pressure from age were derived for systolic and diastolic pressures of males and females. Polynomials to predict blood pressure variance from
J.D. Merrett, T. Wilson
openaire   +3 more sources

Designing for Degradation: Transient Devices Enabled by (Nano)Cellulose

open access: yesAdvanced Materials, EarlyView.
Recent progress in transient devices enabled by (nano)cellulosic materials is reviewed. Transiency mechanisms, advantages of nanocelluloses, and a suite of applications are discussed. A circular thinking approach coupled with life cycle assessment is applied to critically revisit the potential, advantages, and challenges of nanocellulose‐enabled ...
Lucas J. Andrew   +2 more
wiley   +1 more source

Variabilidad en las medidas de tensión arterial realizada por estudiantes de 5.º y 6.º de medicina Variability of arterial pressure measurements performed by advanced medical students

open access: yesEducación Médica, 2008
Introducción. No se ha definido objetivamente si los estudiantes de medicina avanzados dominan destrezas básicas, como la medida de tensión arterial. Sujetos y métodos. Se determinó la variabilidad de medida de tensión arterial por estudiantes de 5.º y 6.
C. Caramelo   +3 more
doaj  

Acute post-exercise change in blood pressure and exercise training response in patients with coronary artery disease

open access: yesFrontiers in Physiology, 2015
We tested the hypothesis that acute post-exercise change in blood pressure (BP) may predict exercise training responses in BP in patients with coronary artery disease (CAD).
Antti M Kiviniemi   +9 more
doaj   +1 more source

Home - About - Disclaimer - Privacy