Results 71 to 80 of about 264,031 (216)

Ischaemic strokes in patients with pulmonary arteriovenous malformations and hereditary hemorrhagic telangiectasia: associations with iron deficiency and platelets. [PDF]

open access: yes, 2014
25/03/14 meb. OA paper , Ok to add.Background: Pulmonary first pass filtration of particles marginally exceeding ~7 µm (the size of a red blood cell) is used routinely in diagnostics, and allows cellular aggregates forming or entering the circulation in ...
John A Livesey   +38 more
core   +1 more source

Successful Hemodialysis Using an Iatrogenic Graft-to-Vein Fistula in Failing Arteriovenous Graft with Chronic Thrombotic Occlusion

open access: yes대한영상의학회지, 2017
An iatrogenic graft-to-vein fistula that develops between a vascular access graft and an adjacent vein is a rare but significant complication. We report a case of an arteriovenous hemodialysis graft (AVG) with an iatrogenic graft-to-vein fistula and a
Yeo Ryang Kang, Jae Hyun Kwon
doaj   +1 more source

Mechanisms and Management of Acquired Aseptic Intracardiac Communications After Transcatheter Aortic Valve Implantation: Single‐Center Case Series Insights

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Background Acquired aseptic intracardiac communications (AICCs) are rare but clinically relevant structural complications following transcatheter aortic valve implantation (TAVI), typically resulting from mechanical injury to the aortic annulus, interventricular septum, or adjacent structures.
Geza Fontos   +6 more
wiley   +1 more source

Immediate use of an arteriovenous prosthetic graft for life-saving dialysis in a child

open access: yes, 2012
Autologous arteriovenous fistulas (AVFs) are the current gold standard for vascular access in hemodialysis (HD). However, in pediatric patients, specific clinical settings may contraindicate the procedure, thus mandating the use of a prosthetic graft (PG)
De Galasso, L   +6 more
core   +1 more source

Left atrial function in uraemic patients: Four‐dimensional automatic left atrial quantitative technology study

open access: yesESC Heart Failure, Volume 12, Issue 2, Page 1316-1325, April 2025.
Abstract Objective This study aimed to evaluate the utility of left atrial volume and function in uraemic patients using four‐dimensional automatic left atrial quantification (4D auto LAQ) technology. Methods Thirty‐four undialysed uraemic patients (U‐ND group), 60 dialysed uraemic patients (U‐D group), and 32 healthy volunteers (N group) were enrolled
Bing Li, Meihua Chen, Xuning Huang
wiley   +1 more source

The outcome of radiocephalic after brachiocephalic and redo arteriovenous fistula

open access: yesSAGE Open Medicine, 2022
Introduction: When created in appropriately selected patients, arteriovenous fistula requires fewer interventions and costs compared to arteriovenous graft.
Bahaa A AL-Madhhachi
doaj   +1 more source

Engineering an artificial trachea: Quantitative benchmarks and modular strategies for mechanics, epithelialization, and vascular integration

open access: yesFlexMat, EarlyView.
In this work, we first examine the limitations of surgical repair and stenting, including migration, granulation, mucus plugging, and infection. We then translate these failures into engineering constraints involving geometry, mechanics, fixation, degradation, junctional stress, and remodeling.
Yiwei Xu   +6 more
wiley   +1 more source

Graft Inclusion Technique – A Unique and Promising Technique of Flow Reduction for High-flow Arteriovenous Fistula in Chronic Kidney Disease Patient

open access: yesIndian Journal of Vascular and Endovascular Surgery
Background: High-flow arteriovenous fistula (AVF) in chronic kidney disease (CKD) patients can lead to complications and challenges in vascular access management. Preserving access while reducing flow is essential for patient care. Objective: To describe
Mahesh Rangapur   +8 more
doaj   +1 more source

Iliac arteriovenous fistula presenting with ascites

open access: yesThe Turkish Journal of Gastroenterology, 2014
Arteriovenous fistula presents rarely with ascites. Diagnosis, with an elusive clinical presentation, is often incidental or delayed. A 35-year-old woman presented with ascites and cardiac decompensation.
Yunus Keser Yılmaz   +8 more
doaj   +1 more source

Validity and agreement of bioelectrical impedance equations against dual energy X‐ray absorptiometry for muscle mass assessment in patients on hemodialysis: A cross‐sectional study

open access: yesNutrition in Clinical Practice, EarlyView.
Abstract Background Low muscle mass is common in patients on hemodialysis (HD), and bioelectrical impedance analysis (BIA) predictive equations have been proposed as an alternative for estimating muscle mass. This study aimed to analyze the validity and agreement of different BIA‐based prediction equations against dual energy X‐ray absorptiometry (DXA)
Sheila Borges   +4 more
wiley   +1 more source

Home - About - Disclaimer - Privacy