Results 21 to 30 of about 8,772 (242)
INDICACIONES DE ESTIMULACIÓN ELÉCTRICA TRANSITORIA, COMPLICACIONES Y NECESIDAD DE ESTIMULACIÓN CARDÍACA PERMANENTE / Use of temporary cardiac pacing, its complications and need for permanent cardiac pacing [PDF]
Resumen: Introducción: La estimulación cardíaca temporal está indicada en diversas situaciones de extrema urgencia, en pacientes con bradiarritmias graves y bloqueos aurículo-ventriculares de II o III grados.Su indicación siempre se considera ante la ...
Humberto Ramos González +5 more
doaj
Pseudopacemaker syndrome and marked first-degree atrioventricular block: Case report [PDF]
Introduction. Pacemaker syndrome consists of the symptoms and signs present in the single chamber (VVI) pacemaker patient with electrode placed in the right ventricular apex.
Panić Miloš +4 more
doaj +1 more source
INTRODUÇÃO: Distúrbios do sistema de condução cardíaco são complicações potenciais e conhecidas dos procedimentos de cirurgia cardíaca valvar. OBJETIVOS: Investigar a associação entre fatores peri-operatórios com bloqueio atrioventricular (BAV) e a ...
Andres Di Leoni Ferrari +7 more
doaj +1 more source
Clinical usage of artificial pacing dates back to 1958, when the battery powered cardiac pacemakers became available. Modern implantable pacemakers are the complicated electronic devices operating 10 years continuously without battery exchange.
core +1 more source
Developing clinical indication for multisite pacing.
The artificial activation of the heart modifies the mechanics of contraction and relaxation. While only little basic research has been addressed to this question, clinical observations showed that for hypertrophic as well as dilated cardiomyopathies ...
Lyon, X. +4 more
core +1 more source
Endocardial left ventricular pacing after accidental aortic wall perforation
Inadvertent endocardial placement of a pacing lead in the left ventricle through the aortic valve is a rare complication with an unknown incidence because of inadequate reporting. Reported cases are usually the result of lead insertion via the subclavian
Raluca Şoşdean +3 more
doaj +1 more source
A brief history of cardiac pacing [PDF]
This article is the first of three articles that will deal with pacing.
Aquilina, Oscar
core
An Artificial Heart System for Testing and Evaluation of Cardiac Pacemakers
The usability assessment of a pacemaker is a complex task where the dedicated programmer for testing programmed algorithms is necessary. This paper provides the outcomes of development and complex testing of the artificial cardiac system to evaluate the ...
Kubicek J. +7 more
core +1 more source
Toward Wireless Implantable Robotic Systems Driven by Magnetic Field for Personalized Therapy
Robotic materials are playing an increasingly vital role in enabling sensing and actuation at small scales. This perspective highlights recent advances in magnetic materials and magnetically actuated devices for wireless sensing, actuation, and energy harvesting toward implantable robotic systems for closed‐loop therapy.
Yusheng Wang, Ruijian Ge, Xiaoguang Dong
wiley +1 more source
Novel direct approach for placement of permanent transvenous pacing leads after Fontan procedure
The need for transvenous pacing (patients who have exhausted epicardial options) after a Fontan-type operation has been recognized. Many novel strategies have been proposed, but currently, all of them require additional maneuvers or rerouting of the ...
Jess T Randall +3 more
doaj +1 more source