Results 51 to 60 of about 2,766,273 (253)

Neuromorphic Electronics for Intelligence Everywhere: Emerging Devices, Flexible Platforms, and Scalable System Architectures

open access: yesAdvanced Materials, EarlyView.
The perspective presents an integrated view of neuromorphic technologies, from device physics to real‐time applicability, while highlighting the necessity of full‐stack co‐optimization. By outlining practical hardware‐level strategies to exploit device behavior and mitigate non‐idealities, it shows pathways for building efficient, scalable, and ...
Kapil Bhardwaj   +8 more
wiley   +1 more source

Biointegrated Battery‐Based Electroceuticals

open access: yesAdvanced Materials, EarlyView.
Biointegrated batteries go beyond passive power to serve as active therapeutic platforms for delivering programmable electrical cues and bioactive agents. This review examines their mechanisms and applications and provides a framework to guide battery‐based therapeutic design and clinical translation.
Yan Zhou   +6 more
wiley   +1 more source

National Security Commission on Artificial Intelligence: Interim Report, November 2019 [PDF]

open access: yes, 2019
Report presenting the National Security Commission on Artificial Intelligence's initial (NSCAI)'s preliminary assessment of artificial intelligence (AI).
National Security Commission on Artificial Intelligence (U.S.)
core  

From Fiber Bundles to Architected Membranes: Triply Periodic Minimal Surface Architectures for Biohybrid Artificial Lungs

open access: yesAdvanced Materials, EarlyView.
Additively manufactured triply periodic minimal surface (TPMS) membranes offer an architecture‐driven alternative to hollow fiber bundles in artificial lungs. Multiphysics simulations and endothelialized prototypes show that the 3D‐printable membrane architecture improves gas exchange, blood flow distribution, and hemocompatibility, enabling ...
Michael Pflaum   +14 more
wiley   +1 more source

The current management of penetrating cardiac trauma [PDF]

open access: yes, 2012
Includes bibliographical references.The vast majority of patients with penetrating cardiac injuries do not reach the hospital alive as the pre-hospital mortality rate for these injuries is in the region of 86%.
Nicol, Andrew John
core   +1 more source

Soft Skins With Reversible Thickness Morphing: Materials, Mechanisms, and Applications

open access: yesAdvanced Materials, EarlyView.
Evolution of electronic skin (e‐skin) technologies toward adaptive, multifunctional soft skins. Phase I highlights early rigid and discrete sensory interfaces. Phase II shows the transition toward flexible, stretchable, and large‐area e‐skin. Phase III captures the emergence of computational e‐skin.
Oliver Ozioko   +2 more
wiley   +1 more source

Implante de marcapasso endocárdico transatrial concomitante a cirurgia com circulação extracorpórea Transatrial endocardial pacemaker implantation associated to open heart surgery with cardiopulmonary bypass

open access: yesBrazilian Journal of Cardiovascular Surgery, 1994
FUNDAMENTO: A utilização de eletrodos epimiocárdicos permanentes tem sido progressivamente abandonada pelos piores resultados que essa técnica apresenta quando comparada aos eletrodos transvenosos.
Roberto Costa   +4 more
doaj  

Pseudopacemaker syndrome and marked first-degree atrioventricular block: Case report [PDF]

open access: yesSrpski Arhiv za Celokupno Lekarstvo, 2010
Introduction. Pacemaker syndrome consists of the symptoms and signs present in the single chamber (VVI) pacemaker patient with electrode placed in the right ventricular apex.
Panić Miloš   +4 more
doaj   +1 more source

National Security Commission on Artificial Intelligence: Initial Report [PDF]

open access: yes, 2019
A brief report summarizing the National Security Commission on Artificial Intelligence's activities, meetings, relationships with the U.S.
National Security Commission on Artificial Intelligence (U.S.)
core  

Wearable Morphology‐Adaptive in‐Ear Device With Active Cleansing Capability for Multimodal Health Monitoring

open access: yesAdvanced Materials, EarlyView.
We present SCIENCE, an in‐ear multimodal physiological monitor featuring two key innovations. Water‐triggered morphological expansion (a 2‐mm cylinder to a 9‐mm spindle) achieves conformal adaptation across complex canal geometries. Simultaneously, active biofouling mitigation disrupts cerumen barriers, reducing sensor‐skin impedance by 20%.
Shuyun Zhuo   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy