Results 51 to 60 of about 59,805 (185)
The Influence of Stem Design and Fixation Methods on the Lifetime of Total Hip Replacement [PDF]
Total hip replacement is one of the most common surgical procedures performed both in the UK and worldwide, with aseptic loosening cited as the primary reason for revision.
Zhang, Hongyu
core +4 more sources
Aseptic loosening of Boneloc R cemented hip prostheses [PDF]
We present a systematic clinical and radiographic study of 147 patients who had total hip replacements from February 1992 to May 1993. BonelocR cement was used in 108, and PalacosR cement with gentamicin in 39 patients who had an increased risk of infection.
N, Wedderkopp +3 more
openaire +2 more sources
Background: The aim of this study was to investigate the efficacy of our modified cementing technique in reducing the rate of aseptic tibial loosening focusing on its relationship with keel length.
Arash Sharafat Vaziri, MD +7 more
doaj +1 more source
Background Total knee arthroplasty (TKA) offers substantially improved function for patients with severe osteoarthritis, but long-term success can be overshadowed by aseptic loosening, a complication with a multifactorial etiology.
Mohammad Ayati Firoozabadi +7 more
doaj +1 more source
Wear of hip prostheses increases serum IGFBP-1 levels in patients with aseptic loosening
The biological mechanisms involved in aseptic loosening include inflammation-associated and bone resorption-associated processes. Coordinated cellular actions result in biochemical imbalances with devastating consequences for the joint.
Gema Vallés +4 more
doaj +1 more source
Radiographic Assessment of Aseptic Loosening of Tumor‐Type Knee Prosthesis in Distal Femur
Objective To measure the full‐length anteroposterior and lateral radiographs of lower limbs after the resection of a tumor in the distal femur and tumor‐type knee prosthesis replacement and to analyze the factors leading to aseptic loosening of the ...
Zi‐ming Li, Xiu‐chun Yu, Kai Zheng
doaj +1 more source
Background and purpose — The Synovasure lateral flow test was developed as a rapid test for the detection or exclusion of periprosthetic joint infection (PJI).
Ruben Scholten +3 more
doaj +1 more source
HYPERSENSITIVITY IN ASEPTIC LOOSENING OF TOTAL HIP REPLACEMENTS
Aseptic loosening is seen in a significant proportion of cemented total hip replacements (THR). In a small subgroup of patients who suffer early loosening polyethylene debris is unlikely to be responsible.
F. S. Haddad +4 more
core +1 more source
ASEPTIC LOOSENING IN CEMENTED CUSTOM-MADE PROSTHETIC REPLACEMENTS FOR BONE TUMOURS OF THE LOWER LIMB
We have made a retrospective study of 1001 custom-made prostheses used as replacements after surgery for bone tumours. There were 493 distal femoral, 263 proximal femoral and 245 proximal tibial prostheses.
P. S. Unwin +5 more
core +1 more source
Early diagnosis of aseptic loosening of hip prosthetic components using acoustic arthrometry
Background. One of the main causes of revision hip arthroplasty is aseptic loosening of prosthetic components. A non-invasive method for early detection of this complication is the assessment of prosthesis condition using a triaxial accelerometer ...
Baikozho R. Tashtanov +4 more
doaj +1 more source

