Results 61 to 70 of about 200,369 (147)
Properties of Concrete with Tire Derived Aggregate Partially Replacing Coarse Aggregates
Tire derived aggregate (TDA) has been proposed as a possible lightweight replacement for mineral aggregate in concrete. The role played by the amount of TDA replacing coarse aggregate as well as different treatment and additives in concrete on its ...
Gideon Siringi +2 more
doaj +1 more source
Synthetic fibres and steel fibres in concrete with regard to bond strength and toughness [PDF]
The ability of fibre reinforced concrete composites to absorb energy has long been recognised as one of the most important benefits of the incorporation of fibres into plain concrete” (Golpalaratham and Gettu 1995).
Landless, Sean, Richardson, Alan
core
The high-temperature corrosion behavior of A1, T22, and T91 steels was investigated in molten nitrate salts at 400, 500, and 600 °C during 100 h of exposure. The combined influence of temperature and chromium content on corrosion kinetics and oxide-scale
R. Felix-Contreras +6 more
doaj +1 more source
Title varies: 1914-19, Membership list; 1947-74, ASTM year book.Mode of access: Internet.Continued by: ASTM ...
American Society for Testing Materials. A. S. T. M. year book. +1 more
core
The master curve brittle fracture toughness estimation method described in the ASTM E1921-11 test standard is based on a theoretical scatter and size effect assumption and makes use of a maximum likelihood estimation method to determine the fracture ...
Wallin, Kim R.W.
core +1 more source
In this paper, joint precast piles with a cross-section of 400 × 400 mm and a pin-joined connection were considered, and their interaction with the soil of Western Kazakhstan has been analyzed.
Abdulla Omarov +6 more
doaj +1 more source
Comparative analysis of test methods for identifying alkali–silica reactivity in concrete aggregates
The alkali–silica reaction (ASR) poses a serious threat to the durability and structural integrity of concrete infrastructure worldwide. This study critically evaluates the effectiveness of ASTM C227 and ASTM C1260 standards in determining the ASR ...
Saleem Muhammad Mazhar +6 more
doaj +1 more source
g. ASTM E761: Compressive Strength of Sprayed Fire-Resistive Materials
1. NFPA requirements for fire resistance ratings of specified areas. 2. Underwriters Laboratories, Inc. (UL): Conform to approved UL designs as published in UL Fire Resistance Directory, in accordance with ASTM E119. 3.
core
Workshop 3 – Reactor Surveillance and Plant Life
Destouches Christophe, Fero Arnold
doaj +1 more source
Workshop 4 – Experimental Techniques
Mutnuru Ravi, Greenwood Larry R.
doaj +1 more source