An Energy Autonomous Microneedle Array‐Based Sensing System for Continuous Biomarker Monitoring
This work presents an innovative self‐powered wearable biosensor system for real‐time monitoring of multiple biomarkers in interstitial fluid. The device integrates stainless steel‐based minimally invasive microneedles with ion‐selective membranes, enabling simultaneous Na+, K+, Ca2+, pH, and glucose detection.
Arnab Pal +9 more
wiley +1 more source
Online Monitoring of Transformer Winding Faults Based on Pulse Coupling Injection. [PDF]
Wang Z +8 more
europepmc +1 more source
Inspired by biological ion transport, this work introduces self‐powered multifunctional sensors utilizing tailored hydrogel stacks. Optimizing ionic migration with MXenes and carbon nanotubes achieves high‐performance energy harvesting and unique logic circuit functionality.
Haoran Chen +9 more
wiley +1 more source
A Self-Powered Vibration Sensing System for High-Voltage Transmission Lines with Equipotential Connections. [PDF]
Zhu X +5 more
europepmc +1 more source
The study proposes a fitting curve as a reference to quantify the optimal K+ ratio in K+/Zn2+ mixed electrolyte, thus achieving stable and high‐capacity aqueous zinc ion batteries at each current density. ABSTRACT Incorporating K+ into Zn‐based electrolytes can enhance the performance of aqueous zinc ion batteries, while the lack of a clear rule for ...
Yewei Li +7 more
wiley +1 more source
Analysis of Influencing Factors in Quantum Chemistry Simulation Based on VQE Algorithm. [PDF]
Zhang M, Kang J, Wu Q, Han B.
europepmc +1 more source
Bias‐Tunable Two‐Terminal Organic Photodetector for Intelligent Imaging
A vertically stacked two‐terminal photodetector with a symmetric donor–acceptor–donor trilayer active exhibits reconfigurable photoresponse with bias‐tunable magnitude and polarity, together with sub‐millisecond response speed and a wide tunable output window.
Sangin Hahn +2 more
wiley +1 more source
Controlling Spatio-Temporal Sequences of Neural Activity by Local Synaptic Changes. [PDF]
Wernecke HO, Lehr AB, Kumar A.
europepmc +1 more source
Sub‐Terahertz Memristor Switches Using MoS2 by Liquid–Liquid Interface Assembly
This work introduces application‐ready sub‐terahertz memristor switches fabricated from electrochemically exfoliated MoS2 nanosheets assembled at a liquid–liquid interface. The devices exhibit robust unipolar resistive switching, low insertion loss, and high isolation across 10–110 GHz.
Tomás Mingates +15 more
wiley +1 more source
Compositional Tuning of Mixed Chromium Monopotassium Phosphates by Ni<sup>2+</sup>/Co<sup>2+</sup> Substitution for Energy Storage Applications. [PDF]
Mighri Z +6 more
europepmc +1 more source

