The main reason that restricts the increase of fast reactor burnup is the irradiation swelling of the cladding. The reported research shows that the main elements and trace alloy/impurity elements have a great influence on the irradiation swelling ...
Bing BAI+5 more
doaj +1 more source
Abstract Purpose Cardiac motion may degrade dose distribution during stereotactic arrhythmia radioablation using the CyberKnife system, a robotic radiosurgery system. This study evaluated the dose distribution changes using a self‐made cardiac dynamic platform that mimics cardiac motion. Methods The cardiac dynamic platform was operated with amplitudes
Takayuki Miyachi+6 more
wiley +1 more source
Contributions to the geology of uranium and thorium by the United States Geological Survey and Atomic Energy Commission for the United Nations International Conference on Peaceful Uses of Atomic Energy, Geneva, Switzerland, 1955 [PDF]
Lincoln R. Page+2 more
openalex +1 more source
Multi‐institutional study on image quality for a novel CBCT solution on O‐ring linac
Abstract Introduction This work presents a multi‐institutional study on image quality provided by a novel cone beam computed tomography (CBCT). The main goal is to investigate the consistency of imaging performance across multiple institutions.
Luis Agulles‐Pedrós+11 more
wiley +1 more source
Abstract This study aimed to evaluate the dose‐exposure reduction effect of a crystalline lens with a bismuth eye shield using cone‐beam computed tomography (CBCT) for head image‐guided radiation therapy. The ocular surface dose of the head phantom (THRA‐1) is defined as a crystalline lens exposure dose and is measured using a radiophotoluminescence ...
Tatsuya Yoshida+5 more
wiley +1 more source
Abstract The thermoluminescence dosimeter (TLD) sheet is a measurement device coated with manganese‐doped LiB3O5 in sheet form. The sheet is 0.2‐mm thick and flexible. Hence, it can fit and be installed on irregular surfaces. The current study aimed to evaluate the feasibility of measuring patient surface doses during radiation therapy using TLD sheets.
Yuya Miyasaka+8 more
wiley +1 more source
Abstract Purpose Single‐isocenter multitarget (SIMT) radiosurgery has become increasingly popular as advancement in planning and delivery systems have made this approach clinically viable. With targets varying in size and distance from isocenter, SIMT plans are highly complex with dynamic multileaf collimator (MLC) motion.
Hem Moktan+3 more
wiley +1 more source