Results 241 to 250 of about 3,894,078 (284)
Some of the next articles are maybe not open access.
Imaging Collagen II Using Atomic Force Microscopy (AFM)
Cold Spring Harbor Protocols, 2010INTRODUCTIONCollagen II is a fibrous protein that assembles from basic tropocollagen subunits to form extracellular supramolecular fiber networks within cartilage tissue. Tropocollagen subunits of ~300 nm in length self-assemble first into pentameric uniform microfibrils, which fuse into bigger collagen fibrils that can range from 10 nm to 500 nm in ...
Marija, Plodinec +2 more
openaire +2 more sources
Atomic Force Microscopy (AFM) Analysis of an Object Larger and Sharper than the AFM Tip
Microscopy and Microanalysis, 2019AbstractAtomic force microscopy (AFM) is typically used for analysis of relatively flat surfaces with topographic features smaller than the height of the AFM tip. On flat surfaces, it is relatively easy to find the object of interest and deconvolute imaging artifacts resulting from the finite size of the AFM tip.
Zhe, Chen +4 more
openaire +2 more sources
Nonlinear distortion in atomic force microscopy (AFM) measurements
Measurement Science and Technology, 2009In AFM measurements it is obvious that the shape of the tip scanning the surface function determines the measurement result: a certain tip radius will result in a remarkable distortion of edges. These effects are usually treated in a more or less heuristic way.
C Hahlweg, M Gruhlke, H Rothe
openaire +1 more source
Technical Aspects of Atomic Force Microscopy (AFM)
2015The design of AFM instruments is in most aspects similar to that used in STM, as discussed in ...
openaire +1 more source
DESIGN OF CANTILEVER PROBES FOR ATOMIC FORCE MICROSCOPY (AFM)
Engineering Optimization, 2000Abstract A cantilever beam used in an Atomic Force Microscope is optimized with respect to two different objectives. The first goal is to maximize the first eigenfrequency while keeping the stiffness of the probe constant. The second goal is to maximize the tip angle of the first eigenmode while again keeping the stiffness constant.
openaire +1 more source
Preparation of microsphere tips for atomic force microscopy (AFM).
Cold Spring Harbor protocols, 2011This protocol describes the preparation and use of spherical indenters for micrometer-scale imaging and mechanical testing with atomic force microscopy (AFM). A spherical indenter is prepared by gluing a hard borosilicate sphere to a tipless cantilever. For this purpose, a stereomicroscope with a micromanipulator attachment is employed. The spheres are
Marija, Plodinec +2 more
openaire +1 more source
Force Curves Restoration in Atomic Force Microscopy (AFM) Resonant Modes
2022 American Control Conference (ACC), 2022openaire +2 more sources

