Results 81 to 90 of about 1,760 (188)
The Influence of Atmospheric Overvoltages on High-Voltage SF6 Substations [PDF]
Very fast overvoltages are characteristic of high-voltage metal-enclosed SF6 insulated substations. During the transient phenomenon, on the SF6 substation enclosure an undesired, short-lasting induced overvoltage may appear, which cannot be prevented ...
Marinko Barukčić +2 more
core +1 more source
Modelling of Power Transformer for Differential Protection Using ATP-EMTP [PDF]
The calculation of electromagnetic transients of a three phase transformer model under differential protection scheme is presented in this paper. Due to certain disadvantages such as expensiveness and prolonged calculation with time consuming it is
et. al., Dr D Prasad,
core +1 more source
KARAKTERISTIK TEGANGAN LEBIH KONDISI TRANSIENT SAAT PROSES ENERGIZED (PEMBERIAN TENAGA) PADA SALURAN TRANSMISI 500 KV [PDF]
Yuniarto, in paper transient overload characteristic at energized prosses on 500 kv transmission line explain that transient over voltage that happened caused switching surge have to be paid attention to don't cause the damage equipments of insulation ...
Yuniarto, Yuniarto
core
Metal oxide surge arresters (ZNO) are used widely in power system to protect equipments from over voltages. Non uniform potential distribution leads to the depressed service life and low safe reliability, so grading ring is applied on HV surge arrester ...
M. Khodsuz, M. Mirzaie
doaj
Wide-band modelling of tower-footing grounding systems based on the impulse response measurement [PDF]
The tower footing grounding system is of major importance for analysis of the lightning overvoltages on an overhead transmission line during backflashover and shielding failure.
Jasika Ranko +3 more
doaj
Electric arc is a complex phenomenon occurring during the current interruption process in the power system. Therefore performing digital simulations is often necessary to analyse transient conditions in power system during switching operations.
Oramus Piotr +4 more
doaj +1 more source
Profil Surja Hubung Karena Proses Energized Pada Saluran Transmisi 500 Kv [PDF]
Transient over voltage that happened because switching surge have to be paid attention to don\u27t cause the damage equipments of insulation coordination system.
Yuniarto, Y. (Yuniarto)
core
Modelado de relés de distancia en ATP-EMTP - Parte 1.pdf
El trabajo completo presenta el modelado de un relé de distancia genérico en el ambiente de transitorio electromagnético (EMT), haciendo uso de las facilidades que ofrece el ATP-EMTP. Se modeló un relé de distancia genérico de característica mho integrado al motor solucionador de ATP.
openaire +1 more source
Evaluation of the backflashover performance of a 150 kV overhead transmission line considering frequency- and current-dependent effects of tower grounding systems [PDF]
The influence of the frequency- and current-dependent response of tower grounding systems on evaluating the backflash over performance of a typical 150 kV overhead transmission line is investigated in this study.
Araneo R. +5 more
core +1 more source
安装线路避雷器是输电线路最有效的防雷方法之一,常规的避雷器安装方式未考虑实际杆塔的结构、地形以及闪络成本等问题,导致技术经济性较差,存在一定的盲目性。为研究避雷器的经济性安装方案,基于ATP-EMTP与电气几何模型建立了同塔双回杆塔电磁暂态分析模型。研究了杆塔结构、地形地貌对双回线路闪络风险的影响,并考虑线路闪络成本对避雷器安装方式的影响,提出利用技术经济性指标W对避雷器不同安装方式下的防雷效果和经济性进行综合评估,当W>0时,避雷器安装具有经济性,W值越大,技术经济性越强。
艾上美, 马御棠, 张林华, 潘浩
doaj