Results 71 to 80 of about 409,669 (384)

Left Atrial Appendage Aneurysm [PDF]

open access: yesThe Annals of Thoracic Surgery, 2016
Left atrial appendage aneurysms (LAAA) are extremely rare. This condition is usually diagnosed incidentally or after the occurrence of thrombotic events or cardiac tachyarrhythmias in the second to fourth decades of life. It can predispose to hazardous adverse events, including atrial fibrillation, myocardial infarction, and systemic thromboembolism ...
Farshad Jalili   +6 more
openaire   +3 more sources

Seeing inside the Body Using Wearable Sensing and Imaging Technologies

open access: yesAdvanced Healthcare Materials, EarlyView.
This review explores wearable technologies for noninvasive internal health monitoring. It categorizes approaches into indirect sensing (e.g., bioelectrical and biochemical signals) and direct imaging (e.g., wearable ultrasound and EIT), highlighting multimodal integration and system‐level innovation toward personalized, continuous healthcare.
Sumin Kim   +3 more
wiley   +1 more source

Electrophysiological Mechanisms of Atrial Flutter [PDF]

open access: yes, 2006
Atrial flutter (AFL) is a common arrhythmia in clinical practice. Several experimental models such as tricuspid regurgitation model, tricuspid ring model, sterile pericarditis model and atrial crush injury model have provided important information about
Chen, Shin-Ann, Tai, Ching- Tai
core   +2 more sources

Mechanisms of postcardiac surgery atrial fibrillation: more pieces in a difficult puzzle [PDF]

open access: yes, 2009
No abstract ...
Antony J. Workman   +13 more
core   +1 more source

Transformative 4D Printed SMPs into Soft Electronics and Adaptive Structures: Innovations and Practical Insights

open access: yesAdvanced Materials Technologies, EarlyView.
This review highlights recent advancements in 3DP techniques that incorporate emerging multifunctional SMP materials for applications in e‐electronics, soft actuators, biomedical devices, and more. Abstract Shape memory polymers (SMP) have recently gained significant attention as multifunctional materials for flexible and wearable electronics ...
Muhammad Yasir Khalid   +4 more
wiley   +1 more source

Cardiac computed tomography angiography‐derived analysis of left atrial appendage morphology and left atrial dimensions for the prediction of atrial fibrillation recurrence after pulmonary vein isolation

open access: yesClinical Cardiology, 2021
Left atrial appendage (LAA) is a potential source of atrial fibrillation (AF) triggers.
F. Straube   +10 more
semanticscholar   +1 more source

Resolution of Occlusive Carotid Artery Thrombus Treated with Anticoagulation as Demonstrated on Duplex Ultrasonography. [PDF]

open access: yes, 2017
BACKGROUND AND PURPOSE: While the majority of cerebral ischemic events due to carotid occlusive disease result from atherosclerotic plaque rupture, intraluminal carotid artery thrombus occasionally occurs in patients without preexisting carotid ...
Liang, John W.   +2 more
core   +2 more sources

Flexible Sensor‐Based Human–Machine Interfaces with AI Integration for Medical Robotics

open access: yesAdvanced Robotics Research, EarlyView.
This review explores how flexible sensing technology and artificial intelligence (AI) significantly enhance human–machine interfaces in medical robotics. It highlights key sensing mechanisms, AI‐driven advancements, and applications in prosthetics, exoskeletons, and surgical robotics.
Yuxiao Wang   +5 more
wiley   +1 more source

Diagnosis of left atrial appendage thrombus in patients with atrial fibrillation: delayed contrast-enhanced cardiac CT

open access: yesEuropean Radiology, 2020
The current reference standard for diagnosing LAA thrombi is transesophageal echocardiography (TEE), a semi-invasive technique. We aimed to devise an optimal protocol for cardiac computed tomography (CCT) in diagnosing left atrial appendage (LAA ...
P. Spagnolo   +7 more
semanticscholar   +1 more source

‘Twiddling’ of the pacemaker resulting in lead dislodgement [PDF]

open access: yes, 2009
Twiddler’s syndrome is a rare condition in which patient manipulation of the pulse generator within its pocket may result in coiling of the lead and lead dislodgement, thereby causing pacemaker malfunction.
Cassar DeMarco, Daniela   +1 more
core  

Home - About - Disclaimer - Privacy