Results 121 to 130 of about 277,450 (285)
Werner Irnich: Pioneer in the Development of the Dual‐Chamber Pacemaker—An Obituary
ABSTRACT Fifty years ago, Werner Irnich presented the concept of an optimal pacemaker capable of responding appropriately to various cardiac arrhythmias and perceptual disturbances, and intended to be used in 85% of patients. With this concept, Irnich was far ahead of his time. His proposed circuitry for AV block and atrial fibrillation, as well as his
Bernd Lemke
wiley +1 more source
Long‐Term Cardiovascular Outcomes Following New‐Onset Arrhythmias During Pregnancy
ABSTRACT Background Arrhythmias during pregnancy are increasingly prevalent and associated with acute adverse cardiovascular outcomes, yet their long‐term cardiovascular implications remain poorly defined. To address this gap, we conducted a large population‐based study to evaluate 5‐year cardiovascular outcomes following incident arrhythmias during ...
Sanya Dhama +4 more
wiley +1 more source
Abstract Background Implantable cardioverter‐defibrillator (ICD) therapy relies on reliable right ventricular leads for pacing, sensing, and defibrillation. The INVICTA DF4 lead is an active‐fixation, quadripolar design intended to optimize implant workflow and long‐term safety and performance. Methods APOLLO was a prospective, multicenter, single‐arm,
Klaus K. Witte +13 more
wiley +1 more source
Catheter ablation of common atrioventricular nodal reentry tachycardia using the conventional method
Background and objective: Atrioventricular nodal reentry tachycardia is the commonest type of supraventricular tachycardia referred to the electrophysiology laboratory.
Amar Alhamdi
doaj
Graphical Abstract ABSTRACT Fluoroscopy has traditionally been the mainstay imaging technique for guidance during electrophysiology (EP) ablation procedures. The numerous disadvantages associated with radiation exposure for both operators and patients have created the need for zero‐fluoroscopy (ZF) approaches. Today, electrophysiologists have access to
Dimitrios Kotzadamis +6 more
wiley +1 more source
First Experience With Extravascular Implantable Cardioverter‐Defibrillator Under Deep Sedation
ABSTRACT Background The Extravascular Implantable Cardioverter‐Defibrillator (EV‐ICD) utilizes a substernal lead to provide defibrillation and anti‐tachycardia pacing (ATP) while avoiding transvenous complications. General anesthesia (GA) was applied for implantation procedures in the EV‐ICD pivotal trial and is currently recommended by the ...
Nibras Soubh +9 more
wiley +1 more source
The following article presents an unusual case of atrial tachycardia, initially misdiagnosed due to a lack of clear P waves.
Shapiro, Michael +5 more
core
ABSTRACT Introduction Pulmonary vein isolation (PVI) alone achieves modest arrhythmia freedom in persistent atrial fibrillation (PeAF). Cryoballoon ablation (CBA) offers a single‐shot alternative to radiofrequency ablation (RFA) that streamlines procedural workflow.
Harroop Bola +8 more
wiley +1 more source
Anatomic-electrophysiological correlations concerning the pathways for atrioventricular conduction. [PDF]
The remarkable success of radiofrequency ablation in recent decades in curing atrioventricular nodal reentrant tachycardias has intensified efforts to provide a solid theoretical basis for understanding the mechanisms of atrioventricular transmission ...
Mazgalev, TN, Anderson, RH, Ho, SY
core
Impact of ICD Presence in Patients With Left Ventricular Assist Devices for End‐Stage Heart Failure
ABSTRACT Background The prognostic relevance of implantable cardioverter defibrillator (ICD) in patients with end‐stage heart failure (HF) with left ventricular assist device (LVAD) remains controversial. Objectives To evaluate the prognostic impact of ongoing use of ICD and associated complications in HF‐patients with LVAD‐implantation.
Nafilah Baridwan +11 more
wiley +1 more source

