Results 201 to 210 of about 83,931 (261)
Adsorption‐Engineered Hydrocarbon Ionomers for Durable Proton‐Exchange Membrane Fuel Cells
Hydrocarbon ionomers suffer from oxidation‐driven interfacial degradation in PEM fuel cell cathodes, leading to catalyst instability. Here, adsorption‐engineered poly(fluorene) ionomers decouple interfacial anchoring from oxidative degradation, enabling strong catalyst–ionomer interactions while resisting electrochemical oxidation.
Heemin Park +14 more
wiley +1 more source
Deep learning approach using SPECT-to-PET translation for attenuation correction in CT-less myocardial perfusion SPECT imaging. [PDF]
Kawakubo M +10 more
europepmc +1 more source
Time-of-flight PET/CT suppresses CT based attenuation correction and scatter coincidence correction errors due to misalignment of the gastrointestinal tract. [PDF]
Watanabe Y, Hosokawa S, Takahashi Y.
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Attenuation Correction in Echocardiography
Ultrasonic Imaging, 1986A commercial two-dimensional echo unit, modified to permit digital acquisition (2.2 MHz) of echo signals prior to time-gain-compensation (TGC), was ratiometrically calibrated. Simulating the TGC in software, we demonstrated improvements in image quality as compared to conventional video methods. A path-dependent attenuation correction (PDAC) algorithm,
M, Pincu +4 more
openaire +3 more sources
A Multivariate Correction for Attenuation
Biometrika, 1975SUMMARY A method is given for the joint correction for attenuation of all pairwise correlations among p variates, subject to the restriction that the resulting correlation matrix be at least positive-semidefinite. The errors need not be assumed uncorrelated, but their covariance matrix must be positive-definite.
Bock, R. Darrell, Petersen, Anne C.
openaire +2 more sources
An introduction to attenuation correction
Journal of Nuclear Cardiology, 1999Attenuation correction techniques have demonstrated improved diagnostic accuracy and quality of myocardial perfusion SPECT images in limited studies. The future success of these methods relies largely on understanding the characteristics of the images and their interpretative meaning, as well as their limitations.
J, Miles, S J, Cullom, J A, Case
openaire +2 more sources
Measured attenuation correction methods
European Journal of Nuclear Medicine, 1989Accurate attenuation correction is a prerequisite for the determination of exact local radioactivity concentrations in positron emission tomography. Attenuation correction factors range from 4-5 in brain studies to 50-100 in whole body measurements. This report gives an overview of the different methods of determining the attenuation correction factors
H, Ostertag +3 more
openaire +2 more sources
The Correction for Attenuation
Educational and Psychological Measurement, 1996This article examines the statistical correction for attenuation and the controversies surrounding the procedure. Although originally developed for test construction purposes, the correction for attenuation is also used in meta-analysis and assessments of validity generalization.
openaire +1 more source
A Semiparametric Correction for Attenuation
Journal of the American Statistical Association, 1994Abstract A correction method is proposed for models including the generalized linear model when the covariate is measured with error. The method requires a separate validation data set that consists of the surrogate W and the true covariate X or an unbiased estimate X⊃ of X.
J. H. Sepanski +2 more
openaire +1 more source
Advances in Attenuation Correction Techniques in PET
PET Clinics, 2007Molecular imaging using PET has evolved from a vigorous academic field into the clinical arena. Considerable advances have been made in the design of high-resolution standalone PET and combined PET/CT units dedicated to clinical whole-body scanning.
Zaidi H, Montandon ML, Alavi A
openaire +3 more sources