Results 241 to 250 of about 1,169,837 (297)
Some of the next articles are maybe not open access.

A Multivariate Correction for Attenuation

Biometrika, 1975
SUMMARY A method is given for the joint correction for attenuation of all pairwise correlations among p variates, subject to the restriction that the resulting correlation matrix be at least positive-semidefinite. The errors need not be assumed uncorrelated, but their covariance matrix must be positive-definite.
Bock, R. Darrell, Petersen, Anne C.
openaire   +2 more sources

An introduction to attenuation correction

Journal of Nuclear Cardiology, 1999
Attenuation correction techniques have demonstrated improved diagnostic accuracy and quality of myocardial perfusion SPECT images in limited studies. The future success of these methods relies largely on understanding the characteristics of the images and their interpretative meaning, as well as their limitations.
J, Miles, S J, Cullom, J A, Case
openaire   +2 more sources

Attenuation Correction of PET/MR Imaging [PDF]

open access: yesMagnetic Resonance Imaging Clinics of North America, 2017
PET/MR is a promising multimodality imaging approach. Attenuation is by far the largest correction required for quantitative PET imaging. MR-based attenuation correction have been extensively pursued, especially for brain imaging, in the past several years. In this article, we review atlas and direct imaging MR-based PET attenuation correction methods.
Hongyu An, Yasheng Chen
exaly   +3 more sources

Measured attenuation correction methods

European Journal of Nuclear Medicine, 1989
Accurate attenuation correction is a prerequisite for the determination of exact local radioactivity concentrations in positron emission tomography. Attenuation correction factors range from 4-5 in brain studies to 50-100 in whole body measurements. This report gives an overview of the different methods of determining the attenuation correction factors
H, Ostertag   +3 more
openaire   +2 more sources

The Correction for Attenuation

Educational and Psychological Measurement, 1996
This article examines the statistical correction for attenuation and the controversies surrounding the procedure. Although originally developed for test construction purposes, the correction for attenuation is also used in meta-analysis and assessments of validity generalization.
openaire   +1 more source

A Semiparametric Correction for Attenuation

Journal of the American Statistical Association, 1994
Abstract A correction method is proposed for models including the generalized linear model when the covariate is measured with error. The method requires a separate validation data set that consists of the surrogate W and the true covariate X or an unbiased estimate X⊃ of X.
J. H. Sepanski   +2 more
openaire   +1 more source

Test Reliability and Correction for Attenuation

Psychometrika, 1950
Evidence is cited to show that specificity, or lack of equivalence, in the comparable forms of tests has a tendency to lower the value of reliability coefficients but has no tendency to lower the value of observed trait coefficients. This implies that the greater the lack of equivalence, the higher will be coefficients corrected for attenuation. Errors
openaire   +2 more sources

Advances in Attenuation Correction Techniques in PET

PET Clinics, 2007
Molecular imaging using PET has evolved from a vigorous academic field into the clinical arena. Considerable advances have been made in the design of high-resolution standalone PET and combined PET/CT units dedicated to clinical whole-body scanning.
Zaidi H, Montandon ML, Alavi A
openaire   +3 more sources

SPECT Attenuation Correction

2015
Abstract Attenuation correction minimizes the impact of body habitus on the acquired myocardial count distribution. The superior diagnostic performance of corrected over uncorrected SPECT images is due to improved specificity and normalcy rate.
Fabio Peroba Esteves, James R. Galt
openaire   +1 more source

Corrections to the attenuation constants of piston attenuators

Proceedings of the IEE - Part III: Radio and Communication Engineering, 1949
The modes existing in a circular waveguide with walls of finite conductivity are investigated and expressions derived for the corrections to the attenuation constant of a piston attenuator. The correction is negligible for E-modes but may be of importance in work of the highest accuracy when H-modes are used.
openaire   +1 more source

Home - About - Disclaimer - Privacy