Results 11 to 20 of about 2,577,898 (160)
A novel method to measure the energy efficiency and performance of an auto-cascade refrigeration cycle [PDF]
Grant TED2021-130162B-I00 funded by MCIN/AEI/ 10.13039/501100011033 and by “ERDF A way of making Europe” by the “European Union”. Grant CIAEST/2021/14 funded by the Generalitat Valenciana. Authors want to acknowledge the company Frost-Trol S.A. (www.frost-trol.com) for the implication in the project and by manufacturing the used refrigerated space, and
Rodrigo Llopis +2 more
openaire +2 more sources
Performance analysis of a modified ejector-enhanced auto-cascade refrigeration cycle
Abstract This paper proposes a novel ejector-enhanced auto-cascade refrigeration cycle (NEARC). In the novel cycle, the ejector not only replaces an expansion valve to recover partial expansion work, but also greatly reduces the throttling loss of the other expansion valve connected to the evaporator.
Shuilong Liu +3 more
+11 more sources
Auto-cascade refrigeration technology has broad application prospects in refrigeration and cryogenic refrigeration owing to its wide operating temperature range, simplicity, and reliability.
Li Yinlong +4 more
doaj +2 more sources
The main objective of this study is to assess both energetically and exergetically the performance of a novel auto-cascade refrigeration (NACR) cycle enhanced by an internal heat exchanger using R290/R170. In contrast to the ACR cycle with a -60 degrees C evaporation temperature, the NACR cycle displays a COP increase of 140.78% and a 148.67 ...
Karaçaylı, İbrahim +2 more
openaire +3 more sources
Energy and exergy analysis of a modified three-stage auto-cascade refrigeration cycle using low-GWP refrigerants for sustainable development. [PDF]
This study proposed a modified three-stage auto-cascade refrigeration cycle (MTARC) operating with environmentally benign zeotropic mixture of R1234yf/R170/R14 at the refrigeration temperature level of - 80 °C. Compared with the conventional three-stage auto-cascade refrigeration cycle (CTARC), MTARC incorporates an additional pressure regulator ...
Qin Y, Li N, Zhang H, Liu B.
europepmc +3 more sources
CO2 as a natural and fully environmentally friendly refrigerant has become more preferable in refrigeration systems in recent years. Since its critical temperature is much lower than that of other refrigerants.
YILMAZ, BARIŞ
core +2 more sources
Characteristics of R134a/R410A Cascade Heat Pump and Optimization [PDF]
Single stage air source heat pump has been widely used around the world. However, it has some drawback, for example, deteriorated heating capacity and COP in cold ambient temperature.
Kim, Min Soo +2 more
core +1 more source
Study on Application of Double-pipe Condenser for Auto-cascade Refrigeration
Auto-cascade refrigeration system is widely used to obtain low temperature environment between -40 ℃ ~ -150 ℃. Double-pipe condenser is commonly regarded for condensing equipment in auto-cascade refrigeration system, its characteristics and structure ...
Zhang Hua +3 more
core +2 more sources
Performance Experiment of R290/CO2 Cascade Refrigeration System [PDF]
Performance experiments of R290/CO2 cascade refrigeration system were conducted. The performance of a cascade refrigeration system having a high temperature cycle using R290 as refrigerant and a CO2 based low temperature cycle was compared with that of a
宁静红, 彭苗, 李惠宇
core +1 more source
This study proposes an absorption-compression cascade refrigeration cycle. The cycle consists of a high-temperature stage combined absorption-compression refrigeration cycle, which is driven by the waste heat of the internal combustion engine, and a low ...
Han Xiaolong +5 more
core +1 more source

