Results 11 to 20 of about 140 (122)
Electric and magnetic comparison of two 10-phase autotransformers
To optimally select multi-pulse rectifiers (MPRs) used in industrial applications, the electrical and magnetic analysis must be performed simultaneously.
Rohollah Abdollahi, Mahdi Golchob
doaj +1 more source
The large current generated by a direct start of the super-large-capacity high-voltage induction motor would have a huge impact on the power grid as well as the motor itself.
Jiaxin Yuan +5 more
doaj +1 more source
UUDAT based on the modular multilevel converter and diode bridges for high-voltage DC application
Conventional unidirectional DC/DC converters for high-voltage direct current application employ DC/AC/DC technology and suffer from high converter cost and power loss.
Meng Zhou +5 more
doaj +1 more source
Interconnection of VSC-HVDC and LCC-HVDC using DC–DC autotransformer
This article investigates the feasibility of interconnecting LCC-HVDC and VSC-HVDC through an un-interrupted DC autotransformer (DC AUTO). The interconnected system aims at taking advantage of two HVDC technologies.
Zhihan Yang +7 more
doaj +1 more source
Autotransformer Monitoring System
This paper describes the monitoring system of autotransformer installed in the Poreba and Bierun substation. Apart from the monitoring system carried out on microprocessor controllers ADAM 5000, a process of adapting the transformer for the system of data acquisition was also described.
Ryszard Kowalik +2 more
openaire +1 more source
For large oil-filled transformers, the oil flow and temperature distribution in transformer windings are an essential issue to be addressed. However, the computation of the oil flow and temperature distribution is a complicated engineering problem ...
Longnv Li +3 more
doaj +1 more source
A New Method of Ground Fault Location in 2 × 25 kV Railway Power Supply Systems
Owing to the installation of autotransformers at regular intervals along the line, distance protection relays cannot be used with the aim of locating ground faults in 2 × 25 kV railway power supply systems.
Jesús Serrano +3 more
doaj +1 more source
Analysis of distribution laws of transformer oil indicators in 110-330 kV transformers
Introduction. Ensuring the operational reliability of power transformers is an urgent task for the power industry in Ukraine and for most foreign countries.
O. Shutenko, S. Ponomarenko
doaj +1 more source
Integral Approach-Based Sensitive Protection of Autotransformers for Turn-to-Turn Faults
Current differential protection, using either phase currents or negative-sequence components, is commonly applied for the sensitive protection of power transformers.
Krzysztof Solak +2 more
doaj +1 more source
A DC/DC autotransformer with integrated fault blocking capability
As crucial equipment for multi-voltage DC interconnection, high-capacity high-voltage DC/DC converters can be used for voltage conversion and DC fault isolation.
LU Yi +5 more
doaj +1 more source