Results 21 to 30 of about 135,105 (102)

First Report on Atrial Leadless Pacing in an Extra-Cardiac Fontan Patient. [PDF]

open access: yesPacing Clin Electrophysiol
ABSTRACT No reports on atrial leadless pacing have been demonstrated in patients with the extra‐cardiac Fontan palliation. We present a case of a patient with an extra‐cardiac Fontan and an alternative to pacing for symptomatic bradycardia in the setting of sinus node dysfunction.
Cortez D.
europepmc   +2 more sources

Combined Application of a Helix-Fixation Leadless Pacemaker and a Subcutaneous Implantable Cardioverter-Defibrillator in a Dialysis Patient: A Case Report. [PDF]

open access: yesClin Case Rep
ABSTRACT Combined use of S‐ICD and LP provides an effective alternative for patients requiring defibrillation and pacing while avoiding transvenous leads. This strategy is particularly valuable for patients with a high risk of infection, though careful consideration must be given to minimizing potential device–device interactions.
Zhou Z, Zhang W, Pang J, Zhou Y.
europepmc   +2 more sources

The Analysis of design and manufacturing tasks using haptic and immersive VR - Some case studies [PDF]

open access: yes, 2007
The use of virtual reality in interactive design and manufacture has been researched extensively but the practical application of this technology in industry is still very much in its infancy.
Ritchie, J.M.   +4 more
core   +4 more sources

First Report on Atrial Leadless Pacing in a Lateral Tunnel Fontan Patient. [PDF]

open access: yesJ Cardiovasc Electrophysiol
ABSTRACT Introduction No reports on atrial leadless pacing have been demonstrated in patients with the Fontan palliation. We present the case of a patient with a Lateral tunnel Fontan palliation with leadless pacing system for symptomatic bradycardia in the setting of sinus node dysfunction. Methods After internal review board approval, a retrospective
Cortez D, Anza OA, Alnoor M.
europepmc   +2 more sources

Segmental Snare Traction Technique for Helix-Fixed Leadless Pacemaker Implantation Across a Repaired Tricuspid Annulus. [PDF]

open access: yesPacing Clin Electrophysiol
ABSTRACT Helix‐fixed leadless pacemaker delivery can be challenging after tricuspid annuloplasty with a rigid ring. An 80‐year‐old woman with prior mitral valve repair, tricuspid annuloplasty (26‐mm MC ring), and Maze III surgery presented with syncope due to atrial fibrillation with a slow ventricular response. Standard maneuvers failed to advance the
Nakamura Y   +5 more
europepmc   +2 more sources

First Confirmed Case of Leadless Pacemaker Insertion via Bidirectional Glenn Shunt in Ebstein's Anomaly: A Novel Approach to Pacing Challenges. [PDF]

open access: yesJ Cardiovasc Electrophysiol
ABSTRACT Background Ebstein's anomaly presents unique pacing challenges due to complex anatomy and surgical history, often leading to transvenous lead complications. Case Presentation A 28‐year‐old male with Ebstein's anomaly, prior Danielson tricuspid valve repair, and bidirectional Glenn shunt presented with acute ventricular pacing loss from ...
Doyle RS   +3 more
europepmc   +2 more sources

Reducing latency when using Virtual Reality for teaching in sport [PDF]

open access: yes, 2008
Latency is a frequently cited shortcoming of Virtual Reality (VR) applications. To compensate for excessive latency, prediction mechanisms may use sophisticated mathematical algorithms, which may not be appropriate for complex virtual teaching ...
Gilbert, Lester   +2 more
core   +2 more sources

Mapping the future: Predictive value of commanded electrogram parameters for the pacing performance in active-fixation leadless pacemakers

open access: yesHeart Rhythm O2
Background: In Aveir VR (Abbott Medical) leadless pacemaker implantation, commanded electrograms (cEGMs) are used before and after fixation to evaluate the suitability of the fixation site.
Takehiro Nomura, MD, PhD   +4 more
doaj   +1 more source

Leadless Pacemaker Implantation in High‐Risk Patients: Real‐World Outcomes From a Multicenter Israeli Registry

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Introduction Transvenous pacemakers are effective but carry significant short‐ and long‐term complications. Leadless pacemakers were developed to overcome these limitations, however, data in high‐risk patients ineligible for transvenous systems remain limited.
Moshe Katz   +7 more
wiley   +1 more source

New-generation Leadless Pacemaker Implantation: First Procedures in Central Asia

open access: yesInterventional Cardiology: Reviews, Research, Resources
In this article, we describe our first experiences implanting the AVEIR VR leadless pacemaker (Abbott) in Kazakhstani patients, a significant step in the development of this technology in Central Asia. This case series includes five male patients, with a
Abay Bakytzhanuly   +2 more
doaj   +1 more source

Home - About - Disclaimer - Privacy