Results 151 to 160 of about 142,021 (310)

Comparison of the noise characteristics of two low pressure ratio fans with a high throat Mach number inlet [PDF]

open access: yes
Acoustics data obtained in experiments with two low pressure ratio 50.8 cm (20 in.) diameter model fans differing in design tip speed were compared.
Abbott, J. M.   +2 more
core   +1 more source

Bioprinting Organs—Science or Fiction?—A Review From Students to Students

open access: yesAdvanced Healthcare Materials, EarlyView.
Bioprinting artificial organs has the potential to revolutionize the medical field. This is a comprehensive review of the bioprinting workflow delving into the latest advancements in bioinks, materials and bioprinting techniques, exploring the critical stages of tissue maturation and functionality.
Nicoletta Murenu   +18 more
wiley   +1 more source

Laser‐Assisted Processing and Modification of Bioactive Glasses: A Review

open access: yesAdvanced Healthcare Materials, EarlyView.
Laser technologies provide powerful tools to process and transform bioactive glasses for advanced biomedical applications. This review discusses laser‐matter interaction mechanisms, laser surface engineering, and laser‐assisted fabrication of scaffolds and nanofibers.
Antonio Riveiro   +8 more
wiley   +1 more source

Jet noise from co-axial nozzles over a wide range of geometric and flow parameters [PDF]

open access: yes
Free field pure jet noise data were taken for a large range of coaxial nozzle configurations. The core nozzles were circular (1 to 4 in. diameter) and plug types.
Friedman, R., Olsen, W.
core   +1 more source

Smart Catheters for Diagnosis, Monitoring, and Therapy

open access: yesAdvanced Healthcare Materials, EarlyView.
This study presents a comprehensive review of smart catheters, an emerging class of medical devices that integrate embedded sensors, robotics, and communication systems, offering increased functionality and complexity to enable real‐time health monitoring, diagnostics, and treatment. Abstract This review explores smart catheters as an emerging class of
Azra Yaprak Tarman   +12 more
wiley   +1 more source

Human Brain Vasculature‐on‐a‐Chip Model Constructed With Microvessels Isolated From Cryopreserved Postmortem Human Brain Tissue

open access: yesAdvanced Healthcare Materials, EarlyView.
This manuscript describes the cultivation of viable microvessels from cryopreserved human brain tissue. When embedded in hydrogels and cultured in microfluidic devices, these microvessels exhibit complex architectures reminiscent of arterioles and capillaries, can be perfused, and display intact barrier function. Collectively, these results demonstrate
Brian J. O'Grady   +5 more
wiley   +1 more source

Investigation of the three-dimensional flow field within a transonic fan rotor: Experiment and analysis [PDF]

open access: yes
An experimental investigation of the three dimensional flow field through a low aspect ratio, transonic, axial flow fan rotor has been conducted using an advanced laser anemometer (LA) system. Laser velocimeter measurements of the rotor flow field at the
Pierzga, M. J., Wood, J. R.
core   +1 more source

Nano‐Engineered Titanium Implants Loaded With Gingival Fibroblasts‐Derived Microvesicles Enhance Early Osseointegration And Soft Tissue Attachment In Vivo

open access: yesAdvanced Healthcare Materials, EarlyView.
Our study showed that human primary gingival fibroblast–derived microvesicles on nano‐engineered titanium implants promote early osseointegration and soft‐tissue attachment in vivo. ABSTRACT Titanium dental implants require both reliable osseointegration and peri‐implant soft tissue seal formation to ensure long‐term success. While osseointegration has
Pingping Han   +10 more
wiley   +1 more source

Bone Healing Around Implants in Normal and Medically Compromised Conditions: Osteoporosis and Diabetes

open access: yesAdvanced Healthcare Materials, EarlyView.
xx xx. ABSTRACT Osseointegration of orthopedic and dental implants is influenced by local and systemic factors, including their physicochemical surface properties and the patient's overall health status. Titanium and its alloys have been a longstanding standard for bone implants due to their innate biocompatibility and mechanical properties.
Dainelys Guadarrama Bello   +2 more
wiley   +1 more source

Performance of a highly loaded two stage axial-flow fan [PDF]

open access: yes
A two-stage axial-flow fan with a tip speed of 1450 ft/sec (442 m/sec) and an overall pressure ratio of 2.8 was designed, built, and tested. At design speed and pressure ratio, the measured flow matched the design value of 184.2 lbm/sec (83.55kg/sec ...
Benser, W. A., Ruggeri, R. S.
core   +1 more source

Home - About - Disclaimer - Privacy