Results 251 to 260 of about 109,720 (300)
Some of the next articles are maybe not open access.

Off-pump Replacement of the INCOR Implantable Axial-flow Pump

The Journal of Heart and Lung Transplantation, 2009
Owing to the actual increase of mechanical circulatory support durations, total or partial replacement of ventricular assist devices (VADs) will most certainly have to be performed with increasing frequency. Herein we report the case of a patient in whom an INCOR (Berlin Heart AG, Berlin) implantable axial-flow pump was replaced without the use of ...
Kuniki, Nakashima   +4 more
openaire   +2 more sources

A Less Invasive Approach to Axial Flow Pump Insertion

The Journal of Heart and Lung Transplantation, 2008
Implantation of a HeartMate II or a Jarvik 2000 FlowMaker left ventricular assist system (LVAS) usually involves a mid-line sternotomy and the use of cardiopulmonary bypass (CPB). In patients with numerous co-morbid conditions, however, surgical trauma may be minimized by implanting the LVAS via a minimally invasive approach, preferably without CPB.In ...
I.D. Gregoric   +7 more
openaire   +3 more sources

The Performance of an Axial-Flow Pump

Proceedings of the Institution of Mechanical Engineers, 1956
Tests were made on an 11-inch diameter axial-flow propeller pump with impeller and guide blades designed for free vortex conditions, using as a basis the modified aerofoil theory. The best overall efficiency obtained was 82 per cent. Apart from head-flow and efficiency characteristics, measurements were made of velocities and yaw angles within the ...
openaire   +1 more source

The Design of Axial Flow Pumps

Journal of Fluids Engineering, 1956
Abstract A design procedure for axial-flow pump impellers is presented that accounts for induced interference effects in the prediction of performance. Induced interference velocities at an impeller blade have been calculated using a three-dimensional model that includes the effects of the other blades and of the total downstream ...
openaire   +1 more source

A Two Stage Axial Flow Pump

ASAIO Journal, 1995
From an engineering point of view, the suitable revolution number for high efficiency operation of an axial flow pump is known. A multistage axial flow pump is a useful tool for reducing revolution number with a high efficiency axial flow pump. A two stage (25) axial flow pump designed at a 5 L/min flow rate and a 100 mmHg pressure head was evaluated ...
Yoshinari Wakisaka   +12 more
openaire   +1 more source

CONE FLOW AND AXIAL FLOW PUMPS

1993
This chapter describes cone flow and axial flow pumps. For low heads up to about 40 m per stage and for type numbers above about 3000, cone flow and axial flow pumps may be used. In general, these pumps have vertical spindles and are arranged to draw water directly from a well or sump, for example, mixed flow pump.
openaire   +1 more source

[The design of axial flow pump].

Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 2002
Axial flow pump has been the hot point of the research field of circulatory support. This article has outlined the basic principle of its design and the methodology of its experimental study, and explained that excellent engineer design, avoiding turbulence, cavitation and wake, and reducing the destroy of red blood cells were the goal to get in design
E, Chen, X, Yu, W, Ding
openaire   +1 more source

Axial flow blood pumps.

ASAIO journal (American Society for Artificial Internal Organs : 1992), 2003
Each year, thousands of cardiac patients await healthy donor hearts for transplantation. Due to the current shortage of donor hearts (approximately 2300 per year), these patients often require supplemental circulatory support until a transplant becomes available. This supplemental support is often provided by a mechanical heart pump or left ventricular
Xinwei, Song   +6 more
openaire   +1 more source

Submersible axial-flow pumps for dredges

Hydrotechnical Construction, 1995
1. For the first time in Russia a submersible axial-flow dredge pump was developed and tested for installation as a first-stage pump on dredges to reduce the negative pressure before the hold dredge pump and to increase its positive suction head. 2.
S. P. Ogorodnikov   +2 more
openaire   +1 more source

Axial Type Self‐Bearing Motor for Axial Flow Blood Pump

Artificial Organs, 2003
Abstract: An axial self‐bearing motor is proposed which can drive an axial blood pump without physical contact. It is a functional combination of the bi‐directional disc motor and the axial active magnetic bearing, where it actively controls single degree‐of‐freedom motion, while other motions such as lateral vibration are passively stable.
Yohji, Okada   +8 more
openaire   +2 more sources