Results 141 to 150 of about 9,885,022 (252)
An explicit constitutive reconstruction framework enables accurate tensile characterization of miniaturized additively manufactured specimens using only the grip‐to‐grip displacement measurements. Progressive validation through self‐consistency, analytical comparison, and inverse finite element method (iFEM) benchmarking demonstrates constitutive ...
Junqing Leng +4 more
wiley +1 more source
Automatic Control Logics to Eliminate Xenon Oscillation Based on Axial Offsets Trajectory Method.
openaire +2 more sources
Intensity Variance-Guided Automated Robotic Optical Coherence Tomography System for Ophthalmic Applications. [PDF]
Su H +8 more
europepmc +1 more source
This study explores the discrepancies between bulk mechanics and spatial mapping in a tissue‐mimetic hydrogel model. Microplastic particles create localized stiff mechanical microenvironments that are detectable by cellular‐scale nanoindentation but leave bulk properties unchanged as measured by rheology.
Ahron T. Verschleisser +3 more
wiley +1 more source
Experimental Investigation on Hybrid Steel-Grout Vertical Joints with Steel Anchor Rings for Precast Concrete Shear Walls. [PDF]
Li Z, Cui B, Han X, Peng Z, Wu Z.
europepmc +1 more source
Binder‐free laser powder bed fusion of 8YSZ with a femtosecond laser is used to map process windows linking scan strategy, heat accumulation, and grain growth. Time‐resolved thermography and simulations reveal thermal regimes that enable continuous, vitrified, and fine‐grained 8YSZ surface layers without absorptive additives and demonstrate ...
Markus Kühn +5 more
wiley +1 more source
A retrospective comparative study of intraoperative fluoroscopy and postoperative radiography for measuring mounting parameters of the taylor spatial frame in tibial fractures. [PDF]
Zhao Z, Cai C, Ji G, Xu W.
europepmc +1 more source
CT‐based finite element simulations combined with in situ X‐ray computed tomography are used to analyze insert pull‐out in nickel‐coated polymer foams. Despite variations in material parameters, deformation consistently concentrates within a narrow annular region around the insert.
Yannik Bautz +4 more
wiley +1 more source
Lateral radial head offset can be associated with chronic epicondylopathia humeri radialis: A new radiological parameter. [PDF]
Vieider RP +7 more
europepmc +1 more source
Design of a Multistable Finger Prosthesis with Programmable Metamaterials
This research article shows the development of a multistable programmble metamaterial for the use as a finger prosthesis. The material was designed on different hierarchical levels where the influence of geometrical parameters and combination of mechanical elements was explored.
Franziska Wenz +5 more
wiley +1 more source

