Results 151 to 160 of about 4,393 (194)
Some of the next articles are maybe not open access.

Related searches:

Minimum Backflow Power and ZVS Design for Dual-Active-Bridge DC–DC Converters

IEEE Transactions on Industrial Electronics, 2023
Junwei Liu, Zheng Dong, Fei Xu
exaly   +2 more sources

Optimal control of DAB converter backflow power based on phase-shifting strategy

Soft Computing, 2020
In order to solve the problems such as high backflow power and current stress of bidirectional DC–DC converter under the traditional single phase-shifting control, an optimized dual phase-shifting control method is proposed. Compared with the conventional phase-shifting control, this method can not only reduce the loss of the converter but also ...
Jinhui Zeng   +4 more
openaire   +1 more source

Voltage and Power Balance Control of Cascaded Power Electronic Transformer With Minimum Power Backflow

2018 Chinese Automation Congress (CAC), 2018
To solve the problem of voltage imbalance at DC side of rectifier stage of the cascaded power electronic transformer, unbalanced transmission power of each DAB module at the isolation stage and power backflow of each DAB module. the paper, on the basis of analyzing the cause of power backflow, deduced the duty ratio at the minimum power backflow in the
, Hongbin Pan
exaly   +2 more sources

Minimum-Backflow-Power Scheme of DAB-Based Solid-State Transformer With Extended-Phase-Shift Control [PDF]

open access: yesIEEE Transactions on Industry Applications, 2018
As key component for the flexible dc distributed power system, the dual active bridge (DAB)-converter-based solid-state transformer (SST) with high efficiency for a wide operating range is essential. However, with the traditional phase-shift control, high backflow power and current stress will significantly affect the conversion efficiency.
Lin Jiang, Guipeng Chen, Haochen Shi
exaly   +3 more sources

Minimum Backflow Power Control of Bidirectional Isolated DC-DC Converters

2018 IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES), 2018
Bidirectional dual-active-bridge (DAB) DC-DC converter with the conventional single-phase-shift (SPS) control may cause large circulating current and high current stress. To overcome these drawbacks, extended-phase-shift (EPS) control can be used in order to improve the efficiency.
Huiqing Wen, Lin Zheng
openaire   +1 more source

Optimal Design Method of LLC Half-Bridge Resonant Converter Considering Backflow Power Analysis

IEEE Transactions on Industrial Electronics, 2022
LLC half-bridge converters have been extensively studied in low power industrial applications. However, the phase shift angle between the voltage and current of the LLC resonant network makes the converter have power circulation, that is, backflow power. The increase of the backflow power will increase the converter conduction loss, which restricts the
Zhe Shi   +4 more
openaire   +1 more source

Sustaining electrification service from photovoltaic power plants during backflow lightning overvoltages

Electric Power Systems Research, 2020
Abstract Photovoltaic (PV) systems are subjected to lightning strikes that contribute to losing their sustainable electrification service. Furthermore, they are subjected to backflow lightning overvoltages due to the installation in high soil resistivity areas, however, such the study is not aforementioned well in the literature.
Nehmdoh A. Sabiha   +5 more
openaire   +1 more source