Assessment of Laser Galvanometer Scanning System Accuracy Using Ball-Bar Standard [PDF]
The laser projector based on the laser galvanometer scanning system enables the projection of CAD-based laser images onto geometrical objects. Furthermore, the system can perform a scan of components in order to control proper positioning (e.g., welded ...
Konrad Kobiela +4 more
doaj +4 more sources
Diagnosis of machine tool with using Renishaw ball-bar system [PDF]
The article deals with accuracy of machine tools. The aim was to determine the accuracy with which already operates used machine – HAAS CNC Milling machine MiniMill.
Čep Robert +5 more
doaj +2 more sources
Evaluation of occlusion and disocclusion time in immediately loaded implant overdentures retained by two splinted versus non-splinted interforaminal implants: A randomized clinical trial [PDF]
Background Mandibular complete dentures often lack stability, leading to prolonged occlusion and disocclusion times. Immediate-loading implant overdentures can improve functional control, but evidence comparing splinted and non-splinted two-implant ...
Omnia M. Refai +2 more
doaj +2 more sources
Comparative Analysis of Retention in Different Attachment Systems for Implant-Supported Overdentures [PDF]
Background: Implant-retained overdentures have become a popular choice in prosthodontics, providing enhanced stability and comfort for edentulous patients. The retention and stability of these overdentures largely depend on the attachment system used.
Ali Alenezi +6 more
doaj +2 more sources
Various methods of circular interpolation performance analysis [PDF]
The paper discusses the possibilities and methodology of utilizing software, designed to be used with a double ball bar device to analyze CNC machine tool positioning performance, to analyze measurements measured by a different method.
Císar Miroslav +2 more
doaj +1 more source
Assessment of peri-implant bone stress distribution with the effect of attachment type and implant location using finite element analysis [PDF]
Background. The objective of the current research was to evaluate how stress is distributed in the peri-implant bone of a mandibular overdenture with implants placed asymmetrically to the midline. Methods.
Shima Aalaei +5 more
doaj +1 more source
Background: Various attachments like ball, bar-clip, magnetic attachments are used in implant supported overdentures. Finite Element Analysis (FEA) a newly innovated technology has been used in dental implantology to evaluate stress distribution patterns.
Bappaditya Bhattacharjee +4 more
doaj +1 more source
Background Robots have been proposed as tools to measure bimanual coordination in children with unilateral cerebral palsy (uCP). However, previous research only examined one task and clinical interpretation remains challenging due to the large amount of ...
Lisa Decraene +8 more
doaj +1 more source
Multi-instrumented dynamic loading experiments on laminated glass [PDF]
Describing quantitatively the response of laminated glass to low-velocity (~5 m/s) impacts by rigid bodies is an important issue because of its significance in terms of structural degradation and integrity, key parameters for people safety and anti ...
Le Gourriérec Corentin +5 more
doaj +1 more source
A novel geometric error identification and prediction approach [PDF]
This paper proposed an integrated geometric error identification and prediction method to solve the uncertainty problem of the PDGEs of rotary axis.
Fan Jinwei, Wang Peitong, Li Zhuang
doaj +1 more source

