Results 71 to 80 of about 2,117 (179)
The 6th International Leh Symposium
Pulmonary Circulation, Volume 12, Issue 3, July 2022.
wiley +1 more source
Estimation of the respiratory rate from ballistocardiograms using the Hilbert transform
Background Measuring the respiratory rate is usually associated with discomfort for the patient due to contact sensors or a high time demand for healthcare personnel manually counting it.
Onno Linschmann +3 more
doaj +1 more source
Motion limitations of non-contact photoplethysmography due to the optical and topological properties of skin [PDF]
Non-contact photoplethysmography (PPG) provides multiple benefits over in-contact methods, but is not as tolerant to motion due to the lack of mechanical coupling between the subject and sensor.
Alametsä J +10 more
core +3 more sources
An Adaptive Feature Extraction Algorithm for Classification of Seismocardiographic Signals
This paper proposes a novel adaptive feature extraction algorithm for seismocardiographic (SCG) signals. The proposed algorithm divides the SCG signal into a number of bins, where the length of each bin is determined based on the signal change within ...
Mansy, Hansen A +2 more
core +1 more source
Low-cost fiber specklegram sensor for noncontact continuous patient monitoring [PDF]
Different low-cost approaches based on fiber specklegram sensors are employed to measure the physiological activity of patients lying in bed. This study is conducted over 20 volunteers to measure the movement and heart rate (HR) using two different ...
Lomer Barboza, Mauro Matías +4 more
core +2 more sources
The utilization of thin and long piezoelectric sensors on compliant substrates allows for the remarkable enhancement of the effective transverse charge constant (d31). The approach is validated using the printable piezoelectric polymer, poly(vinylidene fluoride‐co‐trifluoroethylene) P(VDF‐TrFE).
Peter Zalar +7 more
wiley +1 more source
Bakalářská práce se zabývá návrhem a vývojem softwarového nástroje pro komplexní zpracování a následnou analýzu balistokardiografického signálu (BKG). Software byl vyvinut v interaktivním programové prostředí a skriptovacím programovacím jazyce Matlab v ...
Lančová, Jana
core
We investigated potential factors affecting embryonic heart rate (EHR), a proxy of development, in 14 wild songbird species in east‐central Illinois, USA. Within species we found that EHR was positively associated with embryonic age and egg temperature, while EHR among species were positively associated with nest predation risk.
Alexander J. Di Giovanni +3 more
wiley +1 more source
Machine Learning Outperforms ACC / AHA CVD Risk Calculator in MESA. [PDF]
Background Studies have demonstrated that the current US guidelines based on American College of Cardiology/American Heart Association (ACC/AHA) Pooled Cohort Equations Risk Calculator may underestimate risk of atherosclerotic cardiovascular disease ...
Budoff, Matthew +5 more
core
Heartbeat Rate Measurement from Facial Video [PDF]
Heartbeat Rate (HR) reveals a person’s health condition. This paper presents an effective system for measuring HR from facial videos acquired in a more realistic environment than the testing environment of current systems.
Haque, Mohammad Ahsanul +3 more
core +2 more sources

