Results 71 to 80 of about 629,425 (386)
Effect of using different U/S probe Standoff materials in image geometry for interventional procedures : the example of prostate [PDF]
PURPOSE: This study investigates the distortion of geometry of catheters and anatomy in acquired U/S images, caused by utilizing various stand-off materials for covering a transrectal bi-planar ultrasound probe in HDR and LDR prostate brachytherapy ...
Baltas, Dimos +7 more
core +2 more sources
BACKGROUND AND PURPOSE: Mechanical thrombectomy with proximal flow control and forced aspiration may improve the outcome of endovascular revascularization therapy for patients with acute stroke.
D. E. Jeong +4 more
semanticscholar +1 more source
ABSTRACT Aim Spigelman stage IV duodenal polyposis (SP‐stage IV DP) is associated with high duodenal cancer risk in patients with familial adenomatous polyposis (FAP). This study evaluated the surgical and oncological outcomes of pancreas‐sparing total duodenectomy (PSTD) as a surgical prophylaxis for severe duodenal polyposis in FAP.
Takehiro Shiraishi +8 more
wiley +1 more source
Comparison of transjugular intrahepatic portosystemic shunt with covered stent and balloon-occluded retrograde transvenous obliteration in managing isolated gastric varices [PDF]
OBJECTIVE: Although a transjugular intrahepatic portosystemic shunt (TIPS) is commonly placed to manage isolated gastric varices, balloon-occluded retrograde transvenous obliteration (BRTO) has also been used. We compare the long-term outcomes from these
Kim, Seung Kwon +3 more
core +3 more sources
This retrospective study investigated risk factors for anastomotic stricture and obstructive symptoms following double‐flap technique (DFT) reconstruction after proximal gastrectomy. Mucosal detachment, potentially caused by thermal damage, was identified as a significant risk factor for anastomotic stricture, while continuous suturing at the esophago ...
Shinji Kuroda +9 more
wiley +1 more source
Acute Urinary Obstruction in a Tetraplegic Patient from Misplacement of Catheter in Urethra
A male tetraplegic patient attended accident and emergency with a blocked catheter; on removing the catheter, he passed bloody urine. After three unsuccessful attempts were made to insert a catheter by nursing staff, a junior doctor inserted a three-way ...
Subramanian Vaidyanathan +3 more
doaj +1 more source
Double-Balloon Enteroscopy to Remove a Strangulated Enteroclysis Catheter from the Small Bowel
We present the case of a 77-year-old male who was referred for magnetic resonance (MR) enteroclysis because of small bowel subobstruction. To optimise small bowel distention during MR, a nasojejunal balloon catheter was placed to perfuse iso-osmotic ...
Tom G. Moreels +2 more
doaj +1 more source
Percutaneous Ureteric Stricture Dilation (PCUSD) [PDF]
Ureteric stricture dilation as an interventional uroradiological technique was initiated locally in March 1991. In ureteric dilation two approaches are feasible.
Cutajar, Lino +4 more
core
Management of obstructed balloon catheters. [PDF]
Failure of a balloon catheter to deflate is not uncommon and prevents its removal. Methods of overcoming the problem include traction, bursting the balloon by overinflation, dissolving it with solvents, puncturing it percutaneously with a needle, or puncturing it with a wire stylet passed through the catheter.
G G, Browning, L, Barr, A G, Horsburgh
openaire +2 more sources
This review aims to provide a broad understanding for interdisciplinary researchers in engineering and clinical applications. It addresses the development and control of magnetic actuation systems (MASs) in clinical surgeries and their revolutionary effects in multiple clinical applications.
Yingxin Huo +3 more
wiley +1 more source