Results 51 to 60 of about 102,584 (123)
ABSTRACT Background Transcatheter aortic valve implantation (TAVI) in bicuspid aortic valve (BAV) anatomy remains challenging due to anatomical complexity and limited trial data. New‐generation balloon‐expandable valves, such as Myval, require further evaluation in this subgroup.
Balázs Magyari +11 more
wiley +1 more source
Percutaneous balloon valvuloplasty for bioprosthetic mitral valve stenosis. [PDF]
Percutaneous transcatheter mitral valvuloplasty is the indicated treatment of choice for symptomatic native mitral valve stenosis, but there have been limited reports of successful procedures of balloon valvuloplasty for bioprosthetic mitral valve ...
Imai, Masao +11 more
core +1 more source
Snuffbox approach for balloon aortic valvuloplasty: A case series
In the era of transcatheter aortic valve replacement (TAVR), the spectrum of indications for balloon aortic valvuloplasty is growing, especially in old and frail patients.
Campo G. +7 more
core +1 more source
Transluminal balloon valvuloplasty is an alternative to surgical valvotomy for congenital pulmonary valve stenosis. The aim of this study was to evaluate the long term results (to 13.5 years) of balloon pulmonary valvuloplasty.
Mostafa Behjati-Ardakani +3 more
doaj +2 more sources
The combination of severe aortic stenosis and end-stage liver disease increases the morbidity and mortality of surgical aortic valve replacement or orthotopic liver transplantation resulting in a prohibitive operative risk.
Edward Coverstone +5 more
doaj +1 more source
Mechanism and Immediate Outcome of Significant Mitral Regurgitation Following Balloon Mitral Valvuloplasty with JOMIVA Balloon [PDF]
Introduction: Balloon Mitral Valvuloplasty (BMV) with inoue balloon is the most common technique being followed worldwide. Over the wire BMV is a modified technique with Joseph Mitral Valvuloplasty (JOMIVA) balloon and is being followed in certain ...
Shanmuga Sundaram +5 more
doaj +1 more source
Early Outcomes of Real‐World Aortic Valve Replacement With RESILIA Tissue in the Chinese Population
In this real‐world study of 250 Chinese patients scheduled for elective aortic valve replacement, the INSPIRIS RESILIA aortic valve demonstrated favorable 1‐year safety, with a 98.0% rate of freedom from all‐cause mortality and no observed structural valve deterioration, alongside stable hemodynamic performance.
Haitao Xu +4 more
wiley +1 more source
Left atrial thrombi are common in patients with mitral stenosis. When percutaneous balloon mitral valvuloplasty is performed on such patients, there is a potential risk of thrombus dislodgment and embolization.
Schwinger, Matthew +5 more
core +1 more source
Background: Aortic valve stenosis results from minor to severe degrees of aortic valve maldevelopment. This stenosis causes mild to severe obstruction of the left ventricular outflow .
Hussein A. Alwahab
doaj +1 more source
The patient in this report had a catastrophic case of transcatheter aortic valve replacement–related valve thrombosis manifesting within 1 month of valve implantation that was complicated by acute heart failure and cardiogenic shock.
David Elison, MD, James McCabe, MD
doaj +1 more source