Results 11 to 20 of about 485,645 (257)
Precision Calibration of Radio Interferometers Using Redundant Baselines [PDF]
Growing interest in 21 cm tomography has led to the design and construction of broadband radio interferometers with low noise, moderate angular resolution, high spectral resolution, and wide fields of view.
Liu, Adrian +4 more
core +8 more sources
A self-calibration approach for optical long baseline interferometry imaging [PDF]
Current optical interferometers are affected by unknown turbulent phases on each telescope. In the field of radio-interferometry, the self-calibration technique is a powerful tool to process interferometric data with missing phase information. This paper
Benson +20 more
core +3 more sources
Short Baseline Calibration using GPS and EDM Observations
Una investigación fue conducida para establecer y comparar una línea base de calibración a partir de mediciones realizadas a los GPS (Sistemas de Posicionamiento Global) y de taquímetro electrónico o EDM (Medición Electrónica de Distancia).
Guadalupe Esteban Vazquez Becerra +4 more
doaj +2 more sources
Analysis of the calibration quality of the Kyviskes Calibration Baseline [PDF]
The authors of the paper present analysis of the baseline calibration results that they have performed. The Kyviskės Calibration Baseline (1320 m) is the longest calibration baseline in Lithuania. The baseline was established by the Institute of Geodesy, VGTU in 1996 for calibration of the EDM instruments.
Birvydiene, Rosita +7 more
core +9 more sources
The LOFAR long baseline snapshot calibrator survey [PDF]
Aims. An efficient means of locating calibrator sources for international LOw Frequency ARray (LOFAR) is developed and used to determine the average density of usable calibrator sources on the sky for subarcsecond observations at 140 MHz. Methods. We used the multi-beaming capability of LOFAR to conduct a fast and computationally inexpensive survey ...
Moldón, J. +84 more
+14 more sources
LBCS: The LOFAR Long-Baseline Calibrator Survey [PDF]
(abridged). We outline LBCS (the LOFAR Long-Baseline Calibrator Survey), whose aim is to identify sources suitable for calibrating the highest-resolution observations made with the International LOFAR Telescope, which include baselines >1000 km. Suitable sources must contain significant correlated flux density (50-100mJy) at frequencies around 110 ...
Jackson, N. +78 more
openaire +22 more sources
Study on Calibration of Chromlum(VI) Analyzer [PDF]
This article presents a novel metrological calibration method for trace chromium(VI) analyzer. The study identifies all factors that affect the accuracy of chromium(VI) analyzers, and proposes calibration items and method for the analyzer based on its ...
Peng Jianchun +4 more
doaj +1 more source
Analysis and multi-objective optimisation of wind turbine torque control strategies [PDF]
The combined wind speed estimator and tip-speed ratio (WSE–TSR) tracking wind turbine control scheme has seen recent and increased traction from the wind industry. The modern control scheme provides a flexible trade-off between power and load objectives.
L. Brandetti +5 more
doaj +1 more source
The paper describes a method for the accurate calibration of multi-channel SAR instruments, such as those required to support SAR polarimetry, single-pass interferometry and digital beam-forming (DBF), on the basis of dedicated SAR acquisitions ...
Marc Jäger +2 more
doaj +1 more source
A Novel Airborne Dual-Antenna InSAR Calibration Method for Backprojection Imaging Model
The interferometric synthetic aperture radar (InSAR) elevation inversion method based on the backprojection (BP) imaging model simplifies the interferometric processing chain where image registration and phase unwrapping are not required.
Xiaoning Hu +3 more
doaj +1 more source

