Long Baseline Tightly Coupled DGNSS Positioning with Ionosphere-Free Inter-System Bias Calibration
Based on the statistical stability of the inter-system bias (ISB), we propose a tightly coupled Differential Global Navigation Satellite System (DGNSS) positioning method by using ionosphere-free combination for the long baseline applications.
Jianhua Cheng +5 more
doaj +1 more source
Some issues regarding the calibration of the terrestrial laser scanner Leica Scanstation C10
Some issues regarding the calibration results pertaining to the ground-based laser scanner Leica Scanstation C10 are presented and analysed. The calibration was carried out at Kyviškės Calibration Baseline (Jokela et al.
Urtė Antanavičiūtė +4 more
doaj +1 more source
Positioning Systems for Jiaolong Deep-Sea Manned Submersible: Sea Trial and Application
A crucial issue that cannot be ignored in deep-sea resource surveys and scientific research is underwater positioning and navigation of deep-sea manned submersibles.
Tongwei Zhang, Baohua Liu, Yeyao Liu
doaj +1 more source
Phase and Baseline Calibration for Microwave Interferometric Radiometers Using Beacons [PDF]
The relative phase and amplitude calibration between individual receiving elements are one of the key challenges in interferometric microwave radiometry. For monolithic interferometers, for example the Microwave Imaging Radiometer with Aperture Synthesis (MIRAS) on board the Soil Moisture and Ocean Salinity (SMOS) mission, the calibration of these two ...
Ahmed Kiyoshi Sugihara El Maghraby +5 more
openaire +4 more sources
Calibrating VLBI Polarization Data Using GPCAL. I. Frequency-dependent Calibration
In this series of papers, we present new methods of frequency- and time-dependent instrumental polarization calibration for very long baseline interferometry (VLBI).
Jongho Park +2 more
doaj +1 more source
Optimization of Semiautomated Calibration Algorithm of Multichannel Electrotactile Feedback for Myoelectric Hand Prosthesis [PDF]
The main drawback of the commercially available myoelectric hand prostheses is the absence of somatosensory feedback. We recently developed a feedback interface for multiple degrees of freedom myoelectric prosthesis that allows proprioceptive and sensory
Isaković, Milica +4 more
core +2 more sources
Satellite-Based Evapotranspiration in Hydrological Model Calibration
Hydrological models are usually calibrated against observed streamflow (Qobs), which is not applicable for ungauged river basins. A few studies have exploited remotely sensed evapotranspiration (ETRS) for model calibration but their effectiveness on ...
Lulu Jiang +5 more
doaj +1 more source
This study aimed to make a longitudinal analysis of interexaminer calibration reproducibility in diagnosing dental caries in posterior teeth, by examiners without previous experience in epidemiological studies.
Mariana NABARRETTE +6 more
doaj +1 more source
Polarized Redundant-Baseline Calibration for 21 cm Cosmology Without Adding Spectral Structure [PDF]
21 cm cosmology is a promising new probe of the evolution of visible matter in our universe, especially during the poorly-constrained Cosmic Dawn and Epoch of Reionization.
Aguirre, James E. +10 more
core +2 more sources
In order to investigate quantitatively the accuracy of geomagnetic daily variation recorded by the FGE magnetometer, we analyzed the stability and precision of some groups' baseline values continuously recorded one day at seven observatories in 2009. The
Suqin Zhang, Dongmei Yang
doaj +1 more source

