Results 31 to 40 of about 485,645 (257)
Multi-source self-calibration: Unveiling the microJy population of compact radio sources [PDF]
Context. Very Long Baseline Interferometry (VLBI) data are extremely sensitive to the phase stability of the VLBI array. This is especially important when we reach {\mu}Jy r.m.s. sensitivities.
Barthel, Peter +6 more
core +4 more sources
The LOFAR Long-Baseline Calibrator Survey Classification
Abstract Data manipulation of the LOFAR Long-Baseline Calibrator Survey (LBCS) and the Westerbork Northern Sky Survey (WENSS) catalogues are carried out in the present study. The aim of the study is to make calibrator classification statistics plots and estimations for further observations and upcoming stations.
A. Nikolajevs, K. Prūsis
openaire +1 more source
A 3D tracking system that works with a minimum of two cameras has been implemented. The proposed system consists of two main processes: a calibration process followed by a 3D tracking one. The calibration process is done only when the system is installed;
Juan Andrade
doaj +1 more source
Development of the TanDEM-X Calibration Concept: Analysis of Systematic Errors [PDF]
The TanDEM-X mission, result of the partnership between the German Aerospace Center (DLR) and Astrium GmbH, opens a new era in spaceborne radar remote sensing. The first bistatic satellite synthetic aperture radar mission is formed by flying the TanDEM-
Bachmann, Markus +3 more
core +1 more source
Precise Determination of Calibration Baseline Distances
Some errors that affect the accuracy of electronic distance measurement (EDM) instruments can be determined in a laboratory, but most are detectable and measurable only on a calibration baseline on which distances are precisely determined. In this paper, precise distance determination is presented on the calibration baseline of the Faculty of Geodesy ...
Mladen Zrinjski +2 more
openaire +1 more source
Error Correction of Water Vapor Radiometers for VLBI Observations in Deep-Space Networks
In this paper, we present the design and implementation tests of a water vapor radiometer (WVR) suitable for very long baseline interferometry (VLBI) observation.
Houcai Chen +4 more
doaj +1 more source
The sea surface height (SSH) measured by future wide-swath altimetry satellites contains observation error due to baseline measurement, which is called SSH_Error_Baseline.
Chunyong Ma +8 more
doaj +1 more source
Instantaneous baseline damage localisation using sensor mapping [PDF]
In this paper an instantaneously recorded baseline method is proposed using piezoelectric transducers for damage localisation under varying temperature.
Aliabadi, MH +2 more
core +1 more source
Calibration and Emitters Selection Method of Interferometer Based on Single or Double Emitters [PDF]
The traditional method of joint calibration of fixed baseline interferometer with multiple errors requires more than three calibration emitters to achieve real-time calibration of the interferometer in orbit, but the performance of the traditional method
Song Yihao, Huang Puming, Liu Bo, Feng Xuefeng, Li Shuai, Zhang Qian
doaj +1 more source
Calibration of laser distance meter using Opto-Electronic oscillator
Laser-based Electronic Distance Meters (EDMs) are used extensively to measure inner/outer dimensions in constructions and large volumes. Therefore, it needs to be calibrated regularly to assure its proper function.
Karim Elglmady +3 more
doaj +1 more source

