Review of Scientific Instruments, 1992
Although the types of ion sources in many applications are of great diversity the quality of a source can be assessed mostly by the measurement of the same beam parameters. In this paper the characteristics of various devices for measurement of beam currents, beam profiles, and transverse emittances are discussed.
openaire +1 more source
Although the types of ion sources in many applications are of great diversity the quality of a source can be assessed mostly by the measurement of the same beam parameters. In this paper the characteristics of various devices for measurement of beam currents, beam profiles, and transverse emittances are discussed.
openaire +1 more source
1980
It is often necessary to characterize the beam emitted from a laser to define potential exposure conditions. The beam’s characteristics may be required near the output of the laser, at some considerable distance from the laser after it has been collimated or focused, or simply at some distance after the beam has left the laser cavity as a “ray beam ...
David Sliney, Myron Wolbarsht
openaire +1 more source
It is often necessary to characterize the beam emitted from a laser to define potential exposure conditions. The beam’s characteristics may be required near the output of the laser, at some considerable distance from the laser after it has been collimated or focused, or simply at some distance after the beam has left the laser cavity as a “ray beam ...
David Sliney, Myron Wolbarsht
openaire +1 more source
IEEE Transactions on Nuclear Science, 1965
The detection equipment installed in the Zero Gradient Synchrotron (ZGS) is described. Most measurement techniques and equipment are similar to those of other synchrotrons with the possible exception of fluorescent screens of high transmission viewed by storage TV systems.
openaire +1 more source
The detection equipment installed in the Zero Gradient Synchrotron (ZGS) is described. Most measurement techniques and equipment are similar to those of other synchrotrons with the possible exception of fluorescent screens of high transmission viewed by storage TV systems.
openaire +1 more source
2nd Aerodynamic Testing Conference, 1966
Spectroscopic electron beam diagnostic technique, examining negligible effect elevated vibrational temperatures have on measured rotational temperatures of molecular ...
openaire +1 more source
Spectroscopic electron beam diagnostic technique, examining negligible effect elevated vibrational temperatures have on measured rotational temperatures of molecular ...
openaire +1 more source
1991
The evaluation of the direct beam laser hazards primarily consists of the determination of the NOHD with and without the use of optical devices, and the necessary optical density (OD) required for laser eye protection. The required OD would depend on whether the viewer was located at the laser exit or at a location downrange from the laser.
openaire +1 more source
The evaluation of the direct beam laser hazards primarily consists of the determination of the NOHD with and without the use of optical devices, and the necessary optical density (OD) required for laser eye protection. The required OD would depend on whether the viewer was located at the laser exit or at a location downrange from the laser.
openaire +1 more source
AIP Conference Proceedings, 1989
The emphasis of this paper is ... on frequency domain analysis of beam generated signals in storage rings. The goal is to connect spectrum analyzer observations to what the beam is doing. In addition, understanding beam spectra is essential for understanding coherent effects and instabilities in storage rings, and this is discussed extensively. (AIP)
openaire +1 more source
The emphasis of this paper is ... on frequency domain analysis of beam generated signals in storage rings. The goal is to connect spectrum analyzer observations to what the beam is doing. In addition, understanding beam spectra is essential for understanding coherent effects and instabilities in storage rings, and this is discussed extensively. (AIP)
openaire +1 more source
Diagnostics for radioactive beams
AIP Conference Proceedings, 2001The interest of generating and accelerating beams of unstable nuclei is continuously growing. Following pioneers, new facilities are put into operation or planned. In order to obtain and maintain the highest efficiency, dedicated diagnostics tools have to be developed. The specificities of such devices will be described.
openaire +2 more sources
AIP Conference Proceedings, 1992
In this paper new goals for particle beam diagnostics are discussed in contrast to traditional applications. New accelerator design ideas to produce particle beams of high performance characteristics require a redefinition of beam diagnostics toward more sophisticated beam control and more automation in beam measurements and analysis.
openaire +1 more source
In this paper new goals for particle beam diagnostics are discussed in contrast to traditional applications. New accelerator design ideas to produce particle beams of high performance characteristics require a redefinition of beam diagnostics toward more sophisticated beam control and more automation in beam measurements and analysis.
openaire +1 more source
Abstract The chapter discusses various methods for determining the time profile of electron bunches of sub-picosecond duration, especially methods involving measurements in the frequency domain. Since this type of measurement gives the magnitude of the Fourier transform of the time profile but not its phase, it is necessary to deduce the
openaire +1 more source
openaire +1 more source
Design and Diagnostics of High-Precision Accelerator Neutrino Beams
Applied Sciences (Switzerland), 2021Andrea Longhin +2 more