Results 241 to 250 of about 71,707 (286)
Some of the next articles are maybe not open access.

Simulation and experimental study of beam free hydraulic pumping unit

2017 9th International Conference on Modelling, Identification and Control (ICMIC), 2017
In this paper, the principle of a no beam pumping unit is designed. Based on the AMESim software, established the hydraulic system models. The results of simulation indicate that the pumping unit balance and efficiency has been greatly improved.
Jingchao Chen, Ruibo Yuan, Yongliang Liu
openaire   +1 more source

A Computational Method for Planar Kinematic Analysis of Beam Pumping Units

Journal of Energy Resources Technology, 2007
A generalized computational method for planar kinematic analysis of pumping units is presented in this study. In this method, a local coordinate system is assigned to each body with respect to a fixed global coordinate system. The position of each point in a body is determined by specifying the global translational coordinates of the local coordinate ...
Ramkamal Bhagavatula   +3 more
openaire   +1 more source

Design of beam pumping unit based on virtual prototyping technology

2009 IEEE 10th International Conference on Computer-Aided Industrial Design & Conceptual Design, 2009
The paper introduces virtual prototyping modelling technology of beam pumping unit by Pro/E software. The model is imported to ADAMS software to make kinematics and dynamics simulation; and then is imported to ANSYS software to make finite element method analysis. After optimising parts and structures by ADAMS simulation and ANSYS engineering analysis,
null Fajiang He, null Weiwu Cao
openaire   +1 more source

The Beam Pumping Unit Synchronization Test Data Analysis and the Application

2013 Fifth International Conference on Measuring Technology and Mechatronics Automation, 2013
As the prime working character of beam pumping unit dynamometer card and electrical characteristics can be captured by the high speed synchronous data acquisition with the PC as the core. The motion of beam pumping unit can be divided into four quadrant's according to the crank movement patterns, making use of the synchronization test data the loss can
null Sun Dong   +3 more
openaire   +1 more source

Study of power balance technology on beam pumping unit

Proceedings of 2013 2nd International Conference on Measurement, Information and Control, 2013
Against the balance of beam pumping unit, power technology balance on beam pumping unit is proposed on the basis of kinetic analysis. The balance technology uses RMS minimum power, instead of RMS torque minimum. Oil pumping motor power curve which is satisfied Dirichlet conditions is expanded into convergent trigonometric series.
openaire   +1 more source

Optimization Design of Beam Pumping Unit Based on Response Surface Method

Advanced Materials Research, 2011
An optimization design method is developed for the beam pumping unit, which is based on the API-RP-11L design criteria. The Response Surface Method is used to calculate the structural reliability of the beam pumping unit. The optimization design method not only provides an efficient and fast optimization tool for the modular design of the beam pumping ...
Xiu Juan Yang, Tao Yan, Xiang Zhen Yan
openaire   +1 more source

Experiment Researches of Power Equilibrium Technology for Beam Pumping Unit

2021
A new technology of power equilibrium control is put forward to figure out these problems of beam pumping unit under a constant speed, such as large load fluctuation range, big vibration and poor dynamic performance. The basic principle is that the motor rotation speed is changed in real-time according to the changes to the polished rod load within ...
openaire   +1 more source

Simulation Research On Hydraulic Energy Regulation System of Beam Pumping Unit

2019 IEEE International Conference on Mechatronics and Automation (ICMA), 2019
Because of the unbalanced structure of beam pumping unit, the load torque fluctuates. Moreover, there exists the phenomenon of motor generating in the cycle period of pumping unit. So, the motor often operates under light load for a long time. This will cause serious motor energy consumption.
Chunyou Zhang   +4 more
openaire   +1 more source

Beam-pumping unit energy-saving control system based on support vector machine

2008 IEEE International Conference on Automation and Logistics, 2008
Considering the issues that the energy saving process for beam-pumping unit is a complicated and nonlinear system, and it is very difficult to found the process model to describe it. The support vector machine (SVM) has the ability of strong nonlinear function approach, it has the ability of strong generalization and it also has the feature of global ...
null Meijuan Gao   +3 more
openaire   +1 more source

Design Optimization of Beam-Pumping Unit Based on Improved Particle Swarm Optimization

Applied Mechanics and Materials, 2011
A novel particle swarm optimization algorithm based on chaos searching has been proposed and introduced to optimize the design of beam pumping unit which takes the minimum peak torque factor on the up stroke as the objective function. The optimization for beam-pumping unit have shown the improved particle swarm optimization based on chaos searching ...
Yan Bin Li   +3 more
openaire   +1 more source