Results 181 to 190 of about 14,611,742 (406)

Digital Light Processing of 2D Lattice Composites for Tunable Self‐Sensing and Mechanical Performance

open access: yesAdvanced Engineering Materials, EarlyView., 2023
The study presents the mechanical and in situ sensing performance of digital light processing‐enabled 2D lattice nanocomposites under monotonic tensile and repeated cyclic loading, and provides guidelines for the design of architectures suitable for strain sensors and smart lightweight structures.
Omar Waqas Saadi   +3 more
wiley   +1 more source

Evaluation of daily residual pancreatic tumor motion for deep‐inspiration breath‐hold radiotherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Breath‐hold techniques are widely used in radiation therapy to minimize respiratory‐induced tumor or organ‐at‐risk motion. However, residual motion persists, necessitating a reliable daily evaluation method. Methods At our institution, fiducial markers serve as surrogates for target localization in pancreatic cancer treatment.
Weihua Mao   +4 more
wiley   +1 more source

Creep Characterization of Inconel 718 Lattice Metamaterials Manufactured by Laser Powder Bed Fusion

open access: yesAdvanced Engineering Materials, EarlyView., 2023
Herein, the creep characteristics of additively manufactured Inconel 718 metamaterials are investigated. The creep behavior of metamaterials and the effects of microstructural defects are assessed, and the microstructure defects are accurately captured using Kachanov's creep damage model.
Akash Singh Bhuwal   +5 more
wiley   +1 more source

Obtaining an equivalent beam [PDF]

open access: yes
In modeling a complex structure the researcher was faced with a component that would have logical appeal if it were modeled as a beam. The structure was a mast of a robot controlled gantry crane.
Butler, Thomas G.
core   +1 more source

Quantitative beam optimization for radiotherapy of peripheral lung lesions: A pilot study in stereotactic body radiotherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background To quantify beam optimization for stereotactic body radiotherapy (SBRT) of peripheral lung lesions. Method The new beam optimization approach was based on maximizing the therapeutic gain (TG) of the beam set by minimizing the average physical depth of the lesion with respect to the beam's eye view (BEV).
Hamed Hooshangnejad   +7 more
wiley   +1 more source

Flexural Behavior of Bidirectionally Graded Lattice

open access: yesAdvanced Engineering Materials, EarlyView., 2023
An experimental study of the bending behavior of bidirectional body‐centered cubic lattice beams is conducted in comparison to uniform and unidirectional counterparts of electron beam melted SS 316 L. Experimental results are used to develop and validate a finite element model which is subsequently used to conduct parametric studies to assess the ...
Chamini Rodrigo   +4 more
wiley   +1 more source

Does dose calculation algorithm affect the dosimetric accuracy of synthetic CT for MR‐only radiotherapy planning in brain tumors?

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study compares the dosimetric accuracy of deep‐learning‐based MR synthetic CT (sCT) in brain radiotherapy between the Analytical Anisotropic Algorithm (AAA) and AcurosXB (AXB). Additionally, it proposes a novel metric to predict the dosimetric accuracy of sCT for individual post‐surgical brain cases.
Jeffrey C. F. Lui   +3 more
wiley   +1 more source

A Variational Beam Model for Failure of Cellular and Truss‐Based Architected Materials

open access: yesAdvanced Engineering Materials, EarlyView., 2023
Herein, a versatile and efficient beam modeling framework is developed to predict the nonlinear response and failure of cellular, truss‐based, and woven architected materials. It enables the exploration of their design space and the optimization of their mechanical behavior in the nonlinear regime. A variational formulation of a beam model is presented
Konstantinos Karapiperis   +3 more
wiley   +1 more source

Commissioning a standalone adaptive radiotherapy linac in a multi‐vendor environment

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Current radiotherapy machines intended to perform streamlined online adaptive therapy are designed to be standalone, which makes it challenging to integrate them with the rest of the clinic. This work describes the installation of a standalone CT‐guided online adaptive system, the Varian Ethos, in a busy clinic utilizing products from multiple
Sven Olberg   +4 more
wiley   +1 more source

Home - About - Disclaimer - Privacy