Results 31 to 40 of about 1,577,838 (183)
The contrast transfer function (CTF) is an imaging aberration that is a major resolution‐limiting factor in cryo‐electron microscopy (cryo‐EM). Precise CTF estimation is key to overcoming this limitation, but is particularly challenging in cryo‐electron tomography (cryo‐ET) data. Here, we present an approach for using geometric information to assist in
Sagar Khavnekar, William Wan
wiley +1 more source
The study presents the mechanical and in situ sensing performance of digital light processing‐enabled 2D lattice nanocomposites under monotonic tensile and repeated cyclic loading, and provides guidelines for the design of architectures suitable for strain sensors and smart lightweight structures.
Omar Waqas Saadi+3 more
wiley +1 more source
Depth resolved grazing incidence scattering from the solid-liquid interface
We have applied small angle scattering in grazing incidence beam geometry on a time-of-flight neutron instrument. Due to the broad wavelength distribution provided for a specific incident beam angle the penetration depth of the neutron beam is varied ...
A. J. C. Dennison+6 more
core +1 more source
Decay of polarized muon at rest as a source of polarized neutrino beam [PDF]
In this paper, we indicate the theoretical possibility of using the decay of polarized muons at rest as a source of the transversely polarized electron antineutrino beam. Such a beam can be used to probe new effects beyond standard model.
Abe+30 more
core +2 more sources
Multi‐institutional study on image quality for a novel CBCT solution on O‐ring linac
Abstract Introduction This work presents a multi‐institutional study on image quality provided by a novel cone beam computed tomography (CBCT). The main goal is to investigate the consistency of imaging performance across multiple institutions.
Luis Agulles‐Pedrós+11 more
wiley +1 more source
Creep Characterization of Inconel 718 Lattice Metamaterials Manufactured by Laser Powder Bed Fusion
Herein, the creep characteristics of additively manufactured Inconel 718 metamaterials are investigated. The creep behavior of metamaterials and the effects of microstructural defects are assessed, and the microstructure defects are accurately captured using Kachanov's creep damage model.
Akash Singh Bhuwal+5 more
wiley +1 more source
Abstract Background Volumetric modulated arc therapy (VMAT) requires an accurate patient‐specific quality assurance (PSQA) program. In clinical practice, this is usually performed using the γ‐index and the two‐dimensional gamma passing rate (2D %GP). A three‐dimensional (3D) index incorporating the patient anatomy could be more useful for the 3D dose ...
Christos Zarros+6 more
wiley +1 more source
Flexural Behavior of Bidirectionally Graded Lattice
An experimental study of the bending behavior of bidirectional body‐centered cubic lattice beams is conducted in comparison to uniform and unidirectional counterparts of electron beam melted SS 316 L. Experimental results are used to develop and validate a finite element model which is subsequently used to conduct parametric studies to assess the ...
Chamini Rodrigo+4 more
wiley +1 more source
A review of artificial intelligence in brachytherapy
Abstract Artificial intelligence (AI) has the potential to revolutionize brachytherapy's clinical workflow. This review comprehensively examines the application of AI, focusing on machine learning and deep learning, in various aspects of brachytherapy.
Jingchu Chen+4 more
wiley +1 more source
A Variational Beam Model for Failure of Cellular and Truss‐Based Architected Materials
Herein, a versatile and efficient beam modeling framework is developed to predict the nonlinear response and failure of cellular, truss‐based, and woven architected materials. It enables the exploration of their design space and the optimization of their mechanical behavior in the nonlinear regime. A variational formulation of a beam model is presented
Konstantinos Karapiperis+3 more
wiley +1 more source