Results 71 to 80 of about 4,488 (237)
Background: Although several signals have been proposed to control the activation timing of wearable robots, there is no consensus on the suitability of these signals in terms of their ability to promote effective cooperation and smooth device activation.
Teerapapa Luecha +6 more
wiley +1 more source
Abstract figure legend The long‐term physiological effect of pre‐term birth is a growing area of research. In particular, existing evidence shows unique ventilatory responses to various environmental stimuli in prematurely born adults, suggesting that pre‐term birth modulates chemosensitivity.
Benjamin J. Narang +4 more
wiley +1 more source
Compliant Movement Primitives in a Bimanual Setting
Simultaneously achieving low trajectory errors and compliant control \emph{without} explicit models of the task was effectively addressed with Compliant Movement Primitives (CMP).
Batinica, Aleksandar +4 more
core +1 more source
The purpose of the observations was the viability and quality evaluation of E. coli bacteria encapsulated in hollow fiber membranes (HF) in short in vivo and in vitro experiments.
L. H. Granicka +7 more
doaj +1 more source
Smart laparoscope device was developed and integrated into the ROBIN HEART surgery robot system. Miniaturised silicon based force sensors were developed and integrated into laparoscope tweezers for the special applications. Different sensors were applied
János Radó +14 more
doaj +1 more source
Gaussian Mixture Models for Control of Quasi-Passive Spinal Exoskeletons
Research and development of active and passive exoskeletons for preventing work related injuries has steadily increased in the last decade. Recently, new types of quasi-passive designs have been emerging.
Marko Jamšek, Tadej Petrič, Jan Babič
doaj +1 more source
Abstract Rationale Monitoring physiological strain is recommended to safeguard workers during heat exposure, but is logistically challenging. The perceptual strain index (PeSI) is a subjective estimate thought to reflect the physiological strain index (PSI) that requires no physiological monitoring.
Fergus K. O'Connor +5 more
wiley +1 more source
Abstract Introduction This study examined the impact of different upper‐torso sportswear technologies on the performance and physiological heat strain of well‐trained and national‐level athletes during prolonged running in moderately hot conditions. Methods A randomized crossover design was employed in which 20 well‐trained (n = 16) and national‐level (
Leonidas G. Ioannou +8 more
wiley +1 more source

