Results 151 to 160 of about 3,813,122 (197)
Some of the next articles are maybe not open access.
Lab-on-a-chip systems for biomedical and environmental monitoring
Analytical and Bioanalytical Chemistry, 2003During the last decade, pocket-sized analytical equipment based on the "lab-on-a-chip" approach has become available. These chips, in combination with portable electronic equipment, are applicable in, for example, "point-of-care" ion analysis of body fluids, forensics, identification of explosives, tracking of pollution in environmental or waste waters,
Gardeniers, J.G.E., van den Berg, A.
openaire +5 more sources
Biomedical monitoring of phosphate removal by hemodialysis
Journal of Pharmaceutical and Biomedical Analysis, 2016A compact flow analysis system for non-invasive, dialysate-side monitoring of phosphate removal in the course of clinical hemodialysis treatment is presented. The monitor is based on solenoid operated micro-pumps and extremely cheap optoelectronic flow-through detector allowing photometric determination of phosphate in spent dialysate using a ...
Michał, Michalec +4 more
openaire +2 more sources
A Sensate Liner for Biomedical Monitoring Applications
1998This program develops and demonstrates technologies useful for implementing a manageable cost effective systems approach to monitoring the medical condition of personnel by way of an instrumented uniform hereafter referred to as a Sensate Liner (SL). The SL consists of a form fitting garment which contains and interconnects sensing elements and devices
E J, Lind +6 more
openaire +2 more sources
Biomedical monitoring using electroniccapsule
2015 IEEE International Conference on Microwaves, Communications, Antennas and Electronic Systems (COMCAS), 2015This paper presents a system simulation of wireless telemetry for a bio medical application. The idea is for the patient to swallow a capsule that then travels through the digestive tract or alimentary canal of the human body. Passing internal organs of different sizes and density making the communication between the capsule and the receiver more ...
S. Sayfan-Altman, V. Vulfin
openaire +1 more source
A mobile-based approach to monitor biomedical signals
2015 Medical Technologies National Conference (TIPTEKNO), 2015It developed a model of the human body makes any smart phone that supports the Bluetooth low energy technology process signals sent via the Bluetooth connection of the signals received by sensors (electrode) placed on certain areas. This model, miniature, a flexible substrate that provides low power consumption, low energy-based uses wireless ...
YALMAN, Sakine +2 more
openaire +4 more sources
A versatile biosensor device for continuous biomedical monitoring
Biosensors and Bioelectronics, 2001Although biosensors are by means suitable for continuous biomedical monitoring, due to fouling and blood clotting, in vivo performance is far from optimal. For this reason, ultrafiltration, microdialysis or open tubular flow is frequently used as interface.
Rhemrev-Boom, M. M. +4 more
openaire +4 more sources
Biomedical signals monitoring based in mobile computing
2010 Annual International Conference of the IEEE Engineering in Medicine and Biology, 2010The main objective of this project consists in the development of a biomedical instrumentation prototype for acquisition, processing and transmission of biomedical signals. These biomedical signals are acquired and then processed with a microcontroller. After processing, all data are sent to a communication interface that can send this information to a
Nilton, Serigioli +2 more
openaire +2 more sources
Network architecture for global biomedical monitoring service
2005 IEEE Engineering in Medicine and Biology 27th Annual Conference, 2005Most of the patients who are in hospitals and, increasingly, patients controlled remotely from their homes, at-home monitoring, are continuously monitored in order to control their evolution. The medical devices used up to now, force the sanitary staff to go to the patients' room to control the biosignals that are being monitored, although in many ...
Carmen, Lopez-Casado +7 more
openaire +2 more sources
A biomedical wireless sensor network for hemodynamic monitoring
Proceedings of the Fifth International Conference on Body Area Networks, 2010In the Biomedical Wireless Sensor Network (BWSN) project a consortium of Scandinavian research institutions, technology startup companies, sensor producers, software companies and a hospital based clinical test facility collaborated for 36 months. A portfolio of multiple, experimental wireless sensor prototypes were implemented in sophisticated process
Karl Øyri, Stig Støa, Erik Fosse
openaire +2 more sources
Biomedical analytical monitor of artificial kidney operation: Monitoring of creatinine removal
Journal of Pharmaceutical and Biomedical Analysis, 2016A general concept for the development of flow analysis system for non-invasive, bloodless monitoring of uremic toxins' removal in the course of clinical hemodialysis treatment is presented. The monitor operates in both (discrete and continuous) modes of measurements. In this study as a model uremic marker creatinine has been chosen.
Michał, Michalec +2 more
openaire +2 more sources

