Results 41 to 50 of about 210,559 (109)
Successful Percutaneous Retrieval of an Embolized MitraClip From the Right Subclavian Artery
ABSTRACT Single leaflet device attachment (SLDA) after mitral transcatheter valve edge‐to‐edge repair (M‐TEER) has been reported in up to 5% of patients. However, complete embolization of the M‐TEER device is exceedingly rare. Device retrievals in all previously reported cases were completed by vascular surgery cut down at the end. In this case, we are
Seyed Hossein Aalaei‐Andabili +2 more
wiley +1 more source
A 78-year-old woman with bioprosthetic mitral valve degeneration at high risk for reoperation was referred for transcatheter mitral valve replacement. We describe the use of a preemptive alcohol septal ablation pre-procedurally to minimize the risk of ...
Pedro Engel Gonzalez, MD +4 more
doaj +1 more source
ABSTRACT Background Acquired aseptic intracardiac communications (AICCs) are rare but clinically relevant structural complications following transcatheter aortic valve implantation (TAVI), typically resulting from mechanical injury to the aortic annulus, interventricular septum, or adjacent structures.
Geza Fontos +6 more
wiley +1 more source
PurposeWe examined trends, characteristics and in-hospital outcomes in mechanical and bioprosthetic surgical mitral valve replacement (SMVR) among patients with and without chronic obstructive pulmonary disease (COPD) in Spain from 2001 to 2015.
Javier de-Miguel-Díez +6 more
doaj +1 more source
Early Experience With Evoque Transcatheter Tricuspid Valve Replacement in Carcinoid Heart Disease
ABSTRACT Tricuspid regurgitation (TR) is nearly universal in carcinoid heart disease (CHD), but surgical replacement carries significant risk, and CHD was excluded from the landmark TRISCEND II trial. We present seven patients with CHD undergoing Evoque transcatheter tricuspid valve replacement (TTVR) at two tertiary centers.
Jackson S. Burton +3 more
wiley +1 more source
Dynamic Echocardiographic Imaging of a Valve-in-Valve Mitral Prosthesis
Dynamic imaging of heart valves and specifically prosthetic valves is a central benefit of echocardiography. Most bioprosthetic heart valves degenerate over a given time and hence require repeat valve replacement which carries a significant risk of ...
Bishoy Wassef +4 more
doaj +1 more source
Interventional therapies for chronic heart failure: An overview of recent developments
Abstract Heart failure (HF), the final manifestation of most cardiovascular diseases, has become a major global health concern, affecting millions of individuals. Despite basic drug treatments, patients present with high morbidity and mortality rates. However, recent advancements in interventional therapy have shown promising results in improving the ...
Bingchen Guo +7 more
wiley +1 more source
Occurrence of bioprosthetic valve thrombosis less than a year after replacement is very uncommon. Here, we describe a case of a 57 year old male, who presented 10 months after receiving a bioprosthetic mitral valve replacement with a two week history of ...
Ku Melvin +3 more
doaj +1 more source
Bioinspired passive flow routing mitigates thrombosis in cardiovascular devices by redirecting a small fraction of forward flow into stagnation‐prone regions. Inspired by avian alula and aircraft slat mechanisms, strategically placed routing channels restore washout around mechanical heart valves, reducing low‐shear exposure by four orders of magnitude
Yevgeniy Kreinin +8 more
wiley +1 more source
ABSTRACT Background Pulmonary valve replacement is frequently required in adults with congenital heart disease (CHD). Comparative real‐world outcomes between percutaneous transcatheter pulmonary valve implantation (TPVR) and surgical pulmonary valve replacement (SPVR) remain incompletely characterized. We evaluated outcomes and resource utilization for
Adam Bolad +4 more
wiley +1 more source

