Results 101 to 110 of about 57,287 (257)

Analysis of Pulsatile Vessel Expansion in Healthy, COPD‐and PH‐Patients Using Dynamic Vessel Segmentation in Free‐Breathing Lung MRI

open access: yesJournal of Magnetic Resonance Imaging, EarlyView.
ABSTRACT Background The pulsatile expansion of pulmonary vessels carries dynamic cardiopulmonary information that may reveal disease earlier than structural changes alone. Purpose To test (i) intra‐ and inter‐scan repeatability of dynamic vessel metrics in healthy subjects, and (ii) whether chronic obstructive pulmonary disease (COPD) and postcapillary
Julian Glandorf   +10 more
wiley   +1 more source

Size‐specific dose estimates calculated using patient size measurements from scanned projection radiograph in high‐resolution chest computed tomography

open access: yesJournal of Medical Radiation Sciences, Volume 72, Issue 1, Page 85-92, March 2025.
This study established that patient's lateral width measurements made from scanned projection radiograph (SPR) is an overestimate compared to those measured from tomographic slices by about 10%. Size‐specific dose estimates (SSDE) calculated using lateral width measured from SPR correlates well with SSDE calculated using water equivalent diameter of ...
Ajit Brindhaban
wiley   +1 more source

Phase angle reference values in healthy Chinese adults: A descriptive cross‐sectional study

open access: yesJournal of Parenteral and Enteral Nutrition, EarlyView.
Abstract Background Phase angle serves as a robust indicator of cellular integrity and overall health status. However, reference values for phase angle among healthy Chinese adults remain poorly defined. Methods We performed a multicenter descriptive cross‐sectional study in healthy Chinese adults from 2021 to 2024. Our primary outcome was phase angle,
Na Yang   +5 more
wiley   +1 more source

Novel Device for Measuring Lung Function using Oscillometry [PDF]

open access: yes, 2020
The forced oscillation technique (FOT) is a non-invasive means of measuring lung mechanics. Broad-band oscillations in flow are delivered to the lungs while the resultant pressure oscillations are recorded.
Bates, Jason H.T.   +2 more
core   +1 more source

Radiographic changes in the maxillary sinus following closed sinus augmentation

open access: yesJournal of Periodontology, EarlyView.
Abstract Background The primary objective of this study is to evaluate the accuracy of 3‐dimensional (3D) imaging in detecting radiographic and morphological graft changes compared to traditional 2‐dimensional (2D) imaging. Additionally, the study aims to assess the distribution of graft material and the extent of resorption occurring between baseline ...
Jaret O. Simonsen   +6 more
wiley   +1 more source

Liver Stiffness Characterization of OGTLKO Mouse Model of Progressive Liver Fibrosis

open access: yesJournal of Ultrasound in Medicine, EarlyView.
Objectives O‐GlcNAcylation plays a key regulatory role in hepatic physiology, and its disruption leads to fibrosis in liver‐specific OGT knockout mice (OGTLKO), making this model valuable for studying advanced metabolic dysfunction‐associated steatohepatitis (MASH).
Gilles Renault   +9 more
wiley   +1 more source

Pre‐ and Post‐Interventional Hemodynamic Characterization of the Femoropopliteal Artery Using Vector Flow Imaging in Peripheral Arterial Occlusive Disease

open access: yesJournal of Ultrasound in Medicine, EarlyView.
Objectives The femoropopliteal (FP) artery is the most frequently revascularized segment in peripheral artery disease (PAD), followed by the iliac segment. Wall shear stress (WSS) is a key local factor implicated in both atherosclerotic plaque formation and restenosis after angioplasty.
Jan Lukas Prüser   +5 more
wiley   +1 more source

Home - About - Disclaimer - Privacy