Results 51 to 60 of about 57,287 (257)

Integrated Ultrasound Device for Precision Bladder Volume Monitoring via Acoustic Focusing and Machine Learning

open access: yesAdvanced Science, EarlyView.
We present a conformable wearable ultrasound patch for noninvasive bladder volume monitoring. A flexible PZT array combined with a concave acoustic lens concentrates acoustic energy and improves depth selectivity through the anterior pelvic wall.
Long Long Cao   +4 more
wiley   +1 more source

PERFORMANCE EVALUATION OF NUCLEATED RED BLOOD CELL (NRBC) COUNT USING A FULLY AUTOMATED HAEMATOLOGY ANALYZER VERSUS MANUAL COUNTING

open access: yesPakistan Armed Forces Medical Journal, 2021
Objective: To evaluate the performance of Nucleated RBC (NRBC) Count using a fully automated haematology analyzer versus manual counting. Study Design: Cross-Sectional Study.
Tanweer Ahmed   +5 more
doaj  

Comparison of invasive and non-invasive measurements of cardiac index and systemic vascular resistance in living-donor liver transplantation: a prospective, observational study

open access: yesBMC Anesthesiology, 2023
Background Based on the controversy surrounding pulmonary artery catheterization (PAC) in surgical patients, we investigated the interchangeability of cardiac index (CI) and systemic vascular resistance (SVR) measurements between ClearSight™ and PAC ...
Hye-Yeon Cho   +5 more
doaj   +1 more source

Clinical methods to quantify trunk mobility in an elite male surfing population [PDF]

open access: yes, 2016
Background: Thoracic mobility in the sagittal and horizontal planes are key requirements in the sport of surfing; however to date the normal values of these movements have not yet been quantified in a surfing population. Objectives: To develop a reliable
Abbott, Allan   +4 more
core   +1 more source

Pacinian Corpuscle‐Inspired Strain Conversion Enables Ultrasensitive, Linear, and Broad‐Range Piezoelectric Sensing for Cardiovascular Health Monitoring

open access: yesAdvanced Science, EarlyView.
A bioinspired piezoelectric sensor mimicking Pacinian corpuscles is developed to enable ultrasensitive and linear pressure sensing. A multilayer grooved architecture converts normal pressure into in‐plane strain, delivering high sensitivity, wide linear range, and efficient energy harvesting, enabling high‐fidelity wrist pulse monitoring and ...
Qi Yang   +8 more
wiley   +1 more source

The reliability and validity of a designed setup for the assessment of static back extensor force and endurance in older women with and without hyperkyphosis. [PDF]

open access: yes, 2018
ObjectiveThe purpose of this study was to investigate the intra-rater reliability and validity of a designed load cell setup for the measurement of back extensor muscle force and endurance.ParticipantsThe study sample included 19 older women with ...
Akbarzadeh Baghban, Alireza   +7 more
core   +1 more source

Three Synchronized, Miniaturized, Wireless Inertial Measurement Unit Sensors for Automated Gait and Balance Analysis System

open access: yesAdvanced Intelligent Systems, EarlyView.
This study presents a compact, three IMU wearable system that enables accurate motion capture and robust gait‐feature extraction, thereby supporting reliable machine learning‐based balance evaluation. Accurate assessment of balance is critical for fall prevention and targeted rehabilitation, particularly in older adults and individuals with ...
Seok‐Hoon Choi   +8 more
wiley   +1 more source

Comparison of two cardiac output monitors, qCO and LiDCO, during general anesthesia [PDF]

open access: yes, 2016
Background: Optimization of cardiac output (CO) has been evidenced to reduce postoperative complications and to expedite the recovery. Likewise, CO and other dynamic cardiac parameters can describe the systemic blood flow and tissue oxygenation state and
Escrivá, Jesús   +6 more
core   +1 more source

Toward Harmonizing Quantification of Dopamine Neuron Imaging Biomarkers in Parkinson's Disease: The Centamine Scale

open access: yesAnnals of Neurology, EarlyView.
Objective Dopaminergic imaging is a key biomarker for both the investigation of the biology of Parkinson's disease and related synucleinopathies and the evaluation of potential therapies in clinical trials. This work presents a harmonized approach for quantifying dopaminergic molecular imaging tracers, such as [123I]ioflupane (dopamine transporter scan
Zhen Fan   +174 more
wiley   +1 more source

Non-equivalence of anti-Müllerian hormone automated assays—clinical implications for use as a companion diagnostic for individualised gonadotrophin dosing [PDF]

open access: yes, 2017
STUDY QUESTION Can anti-Müllerian hormone (AMH) automated immunoassays (Elecsys® and Access) be used interchangeably as a companion diagnostic for individualisation of follitropin delta dosing?
Dewailly, Didier   +13 more
core   +2 more sources

Home - About - Disclaimer - Privacy