Results 161 to 170 of about 87,413 (321)

Simultaneous Volumetric T1 and T2 Mapping With Blood‐ and Fat‐Suppression in Abdominal Aortic Aneurysms

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To develop and validate a protocol for simultaneous volumetric T1 and T2 mapping with blood‐ and fat‐suppression, and apply it to patients with abdominal aortic aneurysms (AAA) to assess tissue characteristics. Methods A spoiled gradient echo (SPGR) variable flip angle (VFA) acquisition was modified with preparation modules to suppress
Wilhelm Stehling   +7 more
wiley   +1 more source

Rapid Tissue‐CSF Water Exchange in the Human Brain Revealed by Magnetization Transfer Indirect Spin Labeling

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To apply the Magnetization Transfer Indirect Spin Labeling (MISL) MRI technique for quantifying tissue‐CSF water exchange in the human brain, and to investigate its utility in (1) evaluating tissue‐CSF water exchange within perivascular spaces (PVS), and (2) characterizing altered water exchange dynamics in pathologic conditions ...
Yihan Wu   +8 more
wiley   +1 more source

Verity plots: A novel method of visualizing reliability assessments of artificial intelligence methods in quantitative cardiovascular magnetic resonance.

open access: yesPLoS ONE
BackgroundArtificial intelligence (AI) methods have established themselves in cardiovascular magnetic resonance (CMR) as automated quantification tools for ventricular volumes, function, and myocardial tissue characterization.
Thomas Hadler   +7 more
doaj   +1 more source

Rosette Cardiac MR Fingerprinting for Simultaneous T1, T2, T2*$$ {\mathrm{T}}_2^{\ast } $$, and Fat Fraction Mapping Using a Multi‐Echo Deep Image Prior Reconstruction

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose Quantitative mapping of cardiac tissue properties is used clinically in diagnosis and monitoring of a wide variety of cardiac pathologies. Cardiac Magnetic Resonance Fingerprinting (cMRF) enables rapid and simultaneous quantification of multiple parameters in the myocardium from a single scan.
Evan Cummings   +5 more
wiley   +1 more source

Feasibility of an artificial intelligence system for tumor response evaluation

open access: yesBMC Medical Imaging
Purpose The objective of this study was to evaluate the feasibility of using Artificial Intelligence (AI) to measure the long-diameter of tumors for evaluating treatment response.
Nie Xiuli   +5 more
doaj   +1 more source

A Novel Method for Generating a Fused Ventilation–Perfusion Map Using CT‐Derived Ventilation and FDG‐PET for Lung Functional Avoidance in Radiotherapy: A Feasibility Study

open access: yesPrecision Radiation Oncology, EarlyView.
This study retrospectively analyzed two types of respiratory phase CT and PET/CT images of 20 lung cancer patients. After DIR and functional grading, three lung function images were developed, and their correlations and differences were evaluated. Abstract Background Pulmonary ventilation–perfusion function plays a crucial role in both radiotherapy ...
Suyan Bi   +4 more
wiley   +1 more source

Engineering Dosimetric Excellence In Total Body Irradiation: Tomotherapy‐Driven Protocols for Precision and Reproducibility

open access: yesPrecision Radiation Oncology, EarlyView.
• Objective: Assess helical Tomotherapy‐based TBI for clinical feasibility, dosimetric reproducibility, and in‐vivo accuracy using dual‐orientation simulation and patient‐specific QA. • Methodology: Implementation of ArcCHECK 3D diode array, ionization chamber verification, and in‐vivo dosimetry with OSLDs at 16 anatomical sites to ensure precise dose ...
Sandeep Singh   +8 more
wiley   +1 more source

Sleep assessment using accelerometry: Not all algorithms are equal

open access: yesSleep Research, EarlyView.
Abstract Study objectives Accelerometry devices are increasingly used to assess sleep. However, whether different algorithms provide consistent estimates remains uncertain. This study compared sleep parameters derived from two accelerometry‐based algorithms and a self‐reported sleep journal.
Ruyan Zhou, Pedro Marques‐Vidal
wiley   +1 more source

Pediatric Versus Adult Shear‐Induced Hemolysis—Are Age‐Related Blood Properties the Main Cause for Differences?

open access: yesArtificial Organs, EarlyView.
Graphical summary of the experimental comparison of shear‐induced hemolysis in pediatric and adult blood using a Couette shearing device. Pediatric blood shows a trend toward lower increase in hemolysis at higher shear stress amplitudes, while no relevant differences are observed at low and intermediate stresses.
Vera Froese   +4 more
wiley   +1 more source

Home - About - Disclaimer - Privacy