Results 11 to 20 of about 87,413 (321)

blandaltman: A command to create variants of Bland–Altman plots

open access: yesThe Stata Journal: Promoting communications on statistics and Stata, 2023
Bland–Altman plots can be useful in paired data settings such as measurement-method comparison studies. A Bland–Altman plot has differences, percentage differences, or ratios on the y axis and a mean of the data pairs on the x axis, with 95% limits of agreement indicating the central 95% range of differences, percentage differences, or ratios.
Chatfield, MD   +4 more
openaire   +4 more sources

Bland–Altman agreement analysis between CT predicted and surgical peritoneal cancer index in pseudomyxoma peritonei of appendiceal origin

open access: yesScientific Reports, 2023
Peritoneal cancer index (PCI) is the surgical variable most commonly used to quantify the extent of peritoneal metastases for pseudomyxoma peritonei (PMP) patients.
Mingjian Bai   +8 more
doaj   +2 more sources

Use of the Bland-Altman plot for graphical demonstration of results in the sharing economy

open access: yesEkonomicko-manazerske spektrum, 2020
Today, the sharing economy is a widely discussed topic where people ask themselves what it is, how it works, and what it brings to the society. It occurs in many social spheres; this research paper focuses on the sharing economy in the field of transport.
Catalin Kanty Popescu, Judit Olah
openaire   +2 more sources

Application of the Bland–Altman Plot for Interpretation of Method-Comparison Studies: A Critical Investigation of Its Practice [PDF]

open access: yesClinical Chemistry, 2002
Current guidelines for the combined graphical/statistical interpretation of method-comparison studies (1) include a scatter plot combined with correlation and regression analysis (2) and/or a difference plot combined with calculation of the 2s limits of the differences between the methods (the so-called 95% limits of agreement) (3)(4).
Linda M Thienpont   +3 more
openaire   +2 more sources

A review of Bland–Altman difference plot analysis in the veterinary clinical pathology laboratory

open access: yesVeterinary Clinical Pathology, 2023
AbstractCurrent guidelines recommend using Bland–Altman plots (BA‐plots), also called Difference plots, as part of method comparison evaluation in the veterinary clinical pathology laboratory. Analysis of differences can meaningfully augment linear regression techniques and allows fuller summarization of the performance of two methods relative to each ...
A. R. Moore
openaire   +3 more sources

Validation of spatial microsimulation models: a proposal to adopt the Bland-Altman method [PDF]

open access: yes, 2016
Model validation is recognised as crucial to microsimulation modelling. However, modellers encounter difficulty in choosing the most meaningful methods to compare simulated and actual values. The aim of this paper is to introduce and demonstrate a method
Edwards, Kimberley L., Timmins, Kate A.
core   +2 more sources

Using linear regression to assess dose-dependent bias on a Bland-Altman plot

open access: yesJournal of Emergency and Critical Care Medicine, 2018
Assessing agreement and possible interchangeability between two methods of clinical measurement, when there is no gold standard to compare with, is common in medical research (1,2).
K. Ho
openaire   +2 more sources

Upper stem diameter and volume prediction strategies in the National Forest Inventory of Finland

open access: yesSilva Fennica, 2023
In forest inventories, field data are needed for the prediction of tree volumes. However, gathering field data requires resources, such as labour, equipment, and data management operations.
Virpi Stenman   +2 more
doaj   +1 more source

Tracking wireless bio-medical sensors:result validation with the bland-altman plots [PDF]

open access: yes2008 IEEE Sensors Applications Symposium, 2008
In this paper, we present a series of experimental results of tracking an embedded sensor object similar in physical characteristics to telemetry capsules in the gastro-intestinal (GI) tract using radio frequency (RF) signals. A fair description of implementation detail is given in the body of the paper while focus is on analyzing the experimental ...
Arshak, Khalil, Adepoju, Francis
openaire   +2 more sources

Differences in circulating fatty acid-binding protein 4 concentration in the venous and capillary blood immediately after acute exercise

open access: yesJournal of Physiological Anthropology, 2021
Background Circulating fatty acid-binding protein 4 (FABP4) is a marker for various diseases. It would be highly useful to have simple and less invasive techniques for the assessment of FABP4 concentrations in the clinical research setting.
Shigeharu Numao   +3 more
doaj   +1 more source

Home - About - Disclaimer - Privacy