Results 121 to 130 of about 22,699 (265)

Aortobifemoral Bypass in Kidney Transplant Candidates: A Ten-Year Experience

open access: yesTransplant International
In patients with severe aorto-iliac calcifications, vascular reconstructions can be performed in order to allow kidney transplantation. The aim of this study was to analyze the outcomes of kidney transplant candidates who underwent an aortobifemoral ...
Pascaline Bonnin   +7 more
doaj   +1 more source

Reference Values for Pulse Oximetry Testing in Permanent Teeth: A Systematic Review and Meta‐Analysis

open access: yesInternational Endodontic Journal, EarlyView.
ABSTRACT Background Pulse oximetry is an accurate diagnostic method for assessing the condition of the dental pulp; however, the normal oxygen saturation levels for each tooth type are yet to be clearly defined. Objectives This systematic review and meta‐analysis aims to answer the question: What are the reference values for pulse oximetry testing in ...
Lilian Tietz   +3 more
wiley   +1 more source

Plantar fascia thickness in type 1 diabetes mellitus patients: Clinical associations and metabolic correlates

open access: yesJournal of Diabetes Investigation, EarlyView.
Ultrasound‐measured plantar fascia thickness is associated with microvascular complications and glycemic control in individuals with type 1 diabetes, suggesting PFT as a potential non‐invasive tool for clinical assessment. In addition, improved thickness values were observed in patients using automated insulin delivery systems.
Giulia Casadei   +9 more
wiley   +1 more source

Emergence Profile Angle Matters—Restoring Peri‐Implant Health by Adjusting Prosthetics—A Narrative Review

open access: yesJournal of Esthetic and Restorative Dentistry, EarlyView.
ABSTRACT Objective To review the biological and clinical relevance of prosthetic design, specifically the emergence profile and restorative angle in influencing peri‐implant tissue health, and to illustrate how biologically driven prosthetic modifications can resolve inflammation and support peri‐implant stability.
Miha Pirc   +4 more
wiley   +1 more source

Endovascular Salvage After False Lumen Misdeployment of Thoracic Endovascular Aortic Repair or the Frozen Elephant Trunk in Aortic Dissection: A Case Report of Two Patients

open access: yesVascular Specialist International
Thoracic endovascular aortic repair (TEVAR) and the frozen elephant trunk (FET) are well-established treatment options for aortic dissection (AD). Inadvertent misdeployment of a TEVAR stent graft or FET into the false lumen (FL) can lead to serious ...
Marek Hudák   +2 more
doaj   +1 more source

Load‐To‐Failure of Cantilevered Provisional Implant‐Supported Prostheses: Conventional Versus 3D‐Printed Resins

open access: yesJournal of Esthetic and Restorative Dentistry, EarlyView.
ABSTRACT Objective Cantilever extensions in full‐arch implant‐supported provisional prostheses represent a clinical challenge frequently associated with biomechanical complications. This study aimed to evaluate the load‐to‐failure and deflection of acrylic and 3D‐printed resins used in the cantilever region of implant‐supported provisional prostheses ...
Térsia Cristina Silva Macedo   +4 more
wiley   +1 more source

Prosthetic designs for complete dentures manufactured using contemporary 3D printing techniques: A case series with clinical, design, and laboratory considerations

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Advancements in additive manufacturing have enabled the precise fabrication of complete dentures using modern photopolymers and diverse 3D printing techniques. These innovations have transformed removable prosthodontics by allowing clinicians to design and manufacture highly customized prostheses to manage difficult anatomical and esthetic ...
Francisco X. Azpiazu‐Flores   +4 more
wiley   +1 more source

Biomaterials for Reconstructive Treatment of Peri‐Implantitis

open access: yesJournal of Periodontal Research, EarlyView.
Reconstructive therapy should be implemented in contained defects. Various bone filler materials with or without a barrier membrane and/or adjunctive biologics may be applied. ABSTRACT Peri‐implantitis is a pathological condition affecting the tissues surrounding dental implants, marked by inflammation of the peri‐implant connective tissue and ...
Ausra Ramanauskaite   +3 more
wiley   +1 more source

Soft Tissue Substitutes: Current Biomaterials and Indications at Teeth and Implant Sites

open access: yesJournal of Periodontal Research, EarlyView.
This manuscript provides an updated overview of the current evidence on soft tissue graft substitutes for teeth and dental implants. When appropriately indicated, these biomaterials offer a reliable, less invasive alternative to autogenous grafts, effectively improving root coverage, keratinized mucosa width, and soft tissue thickness with reduced ...
Lorenzo Tavelli   +4 more
wiley   +1 more source

Aneurisma de la aorta abdominal: controversias y tendencias en su diagnóstico y manejo Abdominal aortic aneurysms: Trends and controversies in management

open access: yesRevista Colombiana de Cirugía, 2010
Los aneurismas de aorta abdominal son una alteración frecuente en poblaciones con edad mayor de 65 años. Si se tiene en cuenta que la mayoría de los casos son asintomáticos, esta condición debería ser tamizada en todo paciente con factores de riesgo.
Jairo Ramírez, Marcos E Pozo
doaj  

Home - About - Disclaimer - Privacy