A decade of cardiac surgery after transcatheter aortic valve replacement: Short-term clinical outcomes at a high-volume center. [PDF]
Tagliafierro M +8 more
europepmc +1 more source
An Initial Single-Center European Experience with the Gore Thoracic Branch Endoprosthesis. [PDF]
Dirven M +7 more
europepmc +1 more source
The influence of different transcatheter aortic valve implantation angles, as assessed by multidetector spiral CT scanning, on the depth of valve implantation and its impact on clinical prognosis. [PDF]
Zeng S, Liang X.
europepmc +1 more source
Related searches:
[Urologic complications after implantation of aortofemoral blood vessel prosthesis].
Der Urologe. Ausg. A, 1997After implantation of aorto-femoral grafts, primary ureteral lesions and secondary ureteral obstructions are the most important urological complications. Surgical repair carried out as quickly as possible, including reanastomosis without tension and covering with a peritoneal patch or omentum interposition, seems the best means of preventing secondary ...
H J, Knopf +3 more
openaire +1 more source
[Injury of the inguinal blood vessels in implantation of hip joint prosthesis].
Der Unfallchirurg, 1992Vascular injuries during or after total hip replacements have often been reported. In 2257 artificial hip joint replacements, we observed 8 cases of vascular injuries requiring reconstruction (3 cases), suturing (2 cases), end-to-end anastomosis (1 case), or ligature (2 cases) performed by a vascular surgeon.
M, Staudacher, P, Fasol, C, Wolner
openaire +1 more source
New Method of Hydrophobization of Polyethylene Terephthalate Fabric for Blood Vessel Prosthesis
INEOS OPENThe radical block copolymerization of 2,2,3,3,4,4,4-heptafluorobutyl acrylate (HFBA) with methyl methacrylate (MMA) at 65 °C under normal atmospheric conditions on the surface of polyethylene terephthalate (PET) tissue (Dacron), used for the production of vascular prostheses, was carried out. It was found that the copolymerization of HFBA and MMA in 10:
V. I. Dyachenko, I. S. Chaschin
openaire +1 more source
Can a small blood vessel prosthesis be derived from heterologous foreign body reactive tissue?
Journal of Biomedical Materials Research, 1979AbstractThis study investigated as a small diameter vascular replacement the tissue formed adjacent to an implanted cylindrical foreign body, heterologously transplanted. Grafts of 4 mm i.d. were grown in rabbits and transplanted to dogs as segmental carotid and femoral artery replacements. These maintained 50% patency after 3 weeks.
F J, Schoen +3 more
openaire +2 more sources
[Morphology of abdominal aortic aneurysms with reference to endovascular blood vessel prosthesis].
Swiss surgery = Schweizer Chirurgie = Chirurgie suisse = Chirurgia svizzera, 1996The purpose of this report was to describe the frequency and morphology of infrarenal aortic aneurysms suitable for endovascular tube graft repair. Preoperative abdominal CT scans of 89 patients undergoing open tube graft repair were analyzed retrospectively by measurements of lengths and diameters of the aneurysms.
B, Marty +4 more
openaire +1 more source

