Results 251 to 260 of about 156,036 (282)
Some of the next articles are maybe not open access.
Spectrochimica Acta Part B: Atomic Spectroscopy, 2008
Abstract The aim of this work is to provide a procedure to determine time-resolved electron temperatures with minimized relative errors by the Boltzmann plot method. The applied procedure consists of two parts, a systematic theoretical spectral line selection and an iterative Boltzmann plot algorithm.
Ümit Aydin +3 more
openaire +1 more source
Abstract The aim of this work is to provide a procedure to determine time-resolved electron temperatures with minimized relative errors by the Boltzmann plot method. The applied procedure consists of two parts, a systematic theoretical spectral line selection and an iterative Boltzmann plot algorithm.
Ümit Aydin +3 more
openaire +1 more source
Spectrochimica Acta Part B: Atomic Spectroscopy, 2017
Abstract In this paper we present the application of Independent Component Analysis to a set of time-resolved LIBS spectra, acquired on a brass sample at different delay times. The decomposition of the LIBS spectra in few Independent Components with a given temporal evolution is then exploited for obtaining the temporal evolution of the plasma ...
F. Bredice +11 more
openaire +1 more source
Abstract In this paper we present the application of Independent Component Analysis to a set of time-resolved LIBS spectra, acquired on a brass sample at different delay times. The decomposition of the LIBS spectra in few Independent Components with a given temporal evolution is then exploited for obtaining the temporal evolution of the plasma ...
F. Bredice +11 more
openaire +1 more source
Light, Energy and the Environement 2015, 2015
A new strategy for magnitude of temperature non-uniformity has been investigated based on simulation study and experimental demonstration. It utilized Boltzmann plot to analyze temperature non-uniformity.
Zhang Guangle +3 more
openaire +1 more source
A new strategy for magnitude of temperature non-uniformity has been investigated based on simulation study and experimental demonstration. It utilized Boltzmann plot to analyze temperature non-uniformity.
Zhang Guangle +3 more
openaire +1 more source
Spectrochimica Acta Part B: Atomic Spectroscopy, 2019
Abstract Calibration-free laser-induced breakdown spectroscopy (CF-LIBS) has recently gained attention due to its potential to overcome matrix effects on quantitative analysis using LIBS. However, the efficiency of CF-LIBS may be compromised by uncertainties in the experimental and spectroscopic parameters. To minimize these uncertainties and improve
Luís Carlos Leva Borduchi +2 more
openaire +1 more source
Abstract Calibration-free laser-induced breakdown spectroscopy (CF-LIBS) has recently gained attention due to its potential to overcome matrix effects on quantitative analysis using LIBS. However, the efficiency of CF-LIBS may be compromised by uncertainties in the experimental and spectroscopic parameters. To minimize these uncertainties and improve
Luís Carlos Leva Borduchi +2 more
openaire +1 more source
Microchemical Journal, 1999
A polychromator that allows simultaneous measurements of the emission intensities of multiple lines with different excitation energies was constructed. Thus, temporally resolved Boltzmann plots of iron atomic levels became measurable. The polychromator was applied to a helium radiofrequency atomization/excitation source that was developed for direct ...
Youichiro Kaga +3 more
openaire +1 more source
A polychromator that allows simultaneous measurements of the emission intensities of multiple lines with different excitation energies was constructed. Thus, temporally resolved Boltzmann plots of iron atomic levels became measurable. The polychromator was applied to a helium radiofrequency atomization/excitation source that was developed for direct ...
Youichiro Kaga +3 more
openaire +1 more source
Journal of Analytical Atomic Spectrometry, 2010
The validity of the popular Boltzmann plot method was theoretically tested for the case of a non-homogenious non-isothermal laser-induced plasma. A collisional-dominated plasma model was employed to generate synthetic spectra by solving the radiative transfer equation.
Gornushkin I B +4 more
openaire +2 more sources
The validity of the popular Boltzmann plot method was theoretically tested for the case of a non-homogenious non-isothermal laser-induced plasma. A collisional-dominated plasma model was employed to generate synthetic spectra by solving the radiative transfer equation.
Gornushkin I B +4 more
openaire +2 more sources
International Journal of Nanoscience
In this investigation, a spectroscopic optical emission test was used to investigate the characteristics of gold plasmas that were produced in the surrounding environment using an Nd: YAG system at a wavelength of 1064[Formula: see text]nm and had an energy output that varied from 400 to 600[Formula: see text]mJ. The emission spectrum profiles of (Au)
Hiba A. Abed +2 more
openaire +1 more source
In this investigation, a spectroscopic optical emission test was used to investigate the characteristics of gold plasmas that were produced in the surrounding environment using an Nd: YAG system at a wavelength of 1064[Formula: see text]nm and had an energy output that varied from 400 to 600[Formula: see text]mJ. The emission spectrum profiles of (Au)
Hiba A. Abed +2 more
openaire +1 more source
The 30th International Conference on Plasma Science, 2003. ICOPS 2003. IEEE Conference Record - Abstracts., 2003
Summary form only given, as follows. DC-RF hybrid plasma torches have attracted a great attention to their possible applications to materials synthesis and thermal plasma spray coating by taking advantage of their combined thermal plasma characteristics available from the respective DC and RF torches operating at either atmospheric or reduced pressure ...
J.S. Nam +4 more
openaire +1 more source
Summary form only given, as follows. DC-RF hybrid plasma torches have attracted a great attention to their possible applications to materials synthesis and thermal plasma spray coating by taking advantage of their combined thermal plasma characteristics available from the respective DC and RF torches operating at either atmospheric or reduced pressure ...
J.S. Nam +4 more
openaire +1 more source
Extension of the Boltzmann plot method for multiplet emission lines
Journal of Quantitative Spectroscopy and Radiative Transfer, 2023Tobias Völker, Igor B. Gornushkin
openaire +1 more source
Guang pu xue yu guang pu fen xi = Guang pu, 2004
The present paper analysed in detail the reasons for the errors found in the literature when Boltzmann plot was used for the temperature measurement of a high-density plasma produced by electrothermal capillary discharge. The reliability of experiment can reach as high as 98%-99.5% and the error is only +/- 6.5% when the spectroscopic parameters, such ...
Xiu-yun, Sun +4 more
openaire +1 more source
The present paper analysed in detail the reasons for the errors found in the literature when Boltzmann plot was used for the temperature measurement of a high-density plasma produced by electrothermal capillary discharge. The reliability of experiment can reach as high as 98%-99.5% and the error is only +/- 6.5% when the spectroscopic parameters, such ...
Xiu-yun, Sun +4 more
openaire +1 more source