Results 31 to 40 of about 1,047,382 (357)

Numerical Analysis for the Progressive Failure of Binary-Medium Interface under Shearing

open access: yesAdvances in Civil Engineering, 2018
Binary-medium specimens were fabricated using the particle flow code, and the shear strength, dilatancy, and failure behavior of the binary-medium specimens with different bond strength ratios (0.25, 0.5, 0.75, and 1.0) under different normal stresses ...
Rihong Cao   +3 more
doaj   +1 more source

Study of Bond Strength of Steel Bars in Basalt Fibre Reinforced High Performance Concrete

open access: yesCrystals, 2020
The paper presents the study on bond behaviour of steel bars. It reports the research conducted on local bond strength of short length specimens in high performance concrete (HPC) and basalt fibre reinforced high performance concrete (BFRHPC).
Piotr Smarzewski
doaj   +1 more source

Conductance of a single molecule anchored by an isocyanide substituent to gold electrodes [PDF]

open access: yes, 2006
The effect of anchoring group on the electrical conductance of a single molecule bridging two Au electrodes was studied using di-substituted (isocyanide (CN-), thiol (S-) or cyanide (NC-)) benzene.
Cunningham I. D.   +5 more
core   +2 more sources

Bond Strength of GFRP Bars Embedded in Engineered Cementitious Composite using RILEM Beam Testing

open access: yesInternational Journal of Concrete Structures and Materials, 2018
This paper presents a study on the bond characteristics of glass fiber reinforced polymer (GFRP) bars in engineered cementitious composite (ECC). Ninety beam specimens having variable parameters namely bar diameter, GFRP bar types (standard low modulus ...
Khandaker Muhammed Anwar Hossain
doaj   +1 more source

Experimental study on the bond performance between ultra-high performance concrete and steel bar under freeze-thaw cycles

open access: yesCase Studies in Construction Materials
To study the bond performance of ultra-high performance concrete (UHPC) and steel bar after freeze-thaw cycles (FTCs), the eccentric pull-out test of 10 groups of reinforced UHPC bond specimens, the compressive test of 24 cube specimens and the splitting
Dehong Wang   +3 more
doaj   +1 more source

Analytical carbon-oxygen reactive potential [PDF]

open access: yes, 2008
We present a reactive empirical potential with environment-dependent bond strengths for the carbon-oxygen (CO) system. The distinct feature of the potential is the use of three adjustable parameters characterizing the bond: the strength, length, and ...
Giapis, K. P., Kutana, A.
core   +1 more source

Effect of surface treatments on push-out bond strength of calcium silicate-based cements to fiber posts

open access: yesBMC Oral Health, 2021
Background To evaluate the effect of surface treatments on the push-out bond strength of Biodentine (BD) and white mineral trioxide aggregate (WMTA) to fiber posts. Methods Two brands of fiber posts were used: Reblida post; RP and RelyX post; RX.
Amr M. Elnaghy   +4 more
doaj   +1 more source

Effect of silver diamine fluoride solution application on the bond strength of dentine to adhesives and to glass ionomer cements: a systematic review

open access: yesBMC Oral Health, 2020
Background Silver diamine fluoride (SDF) solution gains increasing popularity in arresting dentine caries in clinical practice. The aim of this systematic review was to summarize the findings from laboratory studies on the influence of SDF application on
Meng Jiang   +4 more
doaj   +1 more source

Making tau amyloid models in vitro: a crucial and underestimated challenge

open access: yesFEBS Letters, EarlyView.
This review highlights the challenges of producing in vitro amyloid assemblies of the tau protein. We review how accurately the existing protocols mimic tau deposits found in the brain of patients affected with tauopathies. We discuss the important properties that should be considered when forming amyloids and the benchmarks that should be used to ...
Julien Broc, Clara Piersson, Yann Fichou
wiley   +1 more source

Kekuatan Geser Semen Ionomer Kaca pada Dentin Gigi Sulung setelah Aplikasi Kondisioner dengan Durasi Berbeda

open access: yesJournal of Dentistry Indonesia, 2015
The bond strength between glass ionomer and tooth structure can be improved with application of conditioner on enamel or dentin surface to remove the smear layer. The bond strength can be measured with shear bond strength testing.
Suzanna Sungkar   +2 more
doaj   +1 more source

Home - About - Disclaimer - Privacy